Use and to choose 11 – 26 for fixed-channel operation, (Au) for auto channel
or (0) to disable the radio. Disabling the radio is useful for extending battery life if,
for example, you have installed the thermostat prior to installing the gateway and/or
control system. Press MODE until the Start infiNET Acquire function is displayed
(AC).

Before an infiNET device can be used on an infiNET network, it must first be
acquired by a C2N-MNETGW gateway that is connected to a Cresnet network.

NOTE: An infiNET device can be acquired by only one gateway.

To acquire the CHV-TSTATRF, perform the following procedure:

1. Ensure the unit is in Setup mode (refer to “Basic Thermostat Setup” on page

15 or “Setup Mode” which starts on page 19) and that Acquire mode (AC)
is selected.

2. Put the C2N-MNETGW in the Acquire mode, from the unit itself by

pressing ACQUIRE or from Toolbox, as described in the latest revision of
the C2N-MNETGW guide (Doc. 6317), which is available for download
from the Crestron website (

http://www.crestron.com/manuals

). The gateway

ACQUIRE LED lights.

NOTE: In environments where multiple gateways are installed, only one
gateway should be in Acquire mode at a time.

3. Press and simultaneously on the CHV-TSTATRF to start the acquire

process: display shows flashing “—” (in progress). When finished, display
shows “00” (finished, found gateway) or “E#” (finished, could not find
gateway), where # represents an error code.

NOTE: The acquire process can take up to five minutes, depending on the RF
channel. Please allow enough time for process to complete.

NOTE: “E0” indicates that search time has expired and no gateway was found.
“E1” indicates the RF channel is set to “0” (disabled). To enable the RF channel,
refer to “infiNET RF Channel” in “Setup Mode Parameters/Functions” which starts
on page 20.

NOTE: To cancel an acquire process before it has completed, press the and
buttons simultaneously.

After the process is complete, take the C2N-MNETGW out of the Acquire mode by
pressing ACQUIRE on the gateway. Refer to the latest revision of the
C2N-MNETGW guide (Doc. 6317).

To exit from Setup mode, press the FAN button on the CHV-TSTATRF.

The Fan icon will indicate the status of infiNET communication:

• Solid (non-blinking): Communication with control processor established

via gateway.

• Two brief blinks every eight seconds: Communication with gateway

established but control system is not addressing this MNET ID. It is
possible the MNET ID of the device (or the gateway ID) is not set to match
the MNET ID of the D3 Pro, SystemBuilder or SIMPL Windows program.
Use the Network Device Tree in Crestron Toolbox to poll the infiNET

Operations & Installation Guide – DOC. 6490A

infiNET™ Thermostat: CHV-TSTATRF