Software-Controlled STORE/RECALL Cycle
In the following table, the software controlled STORE and RECALL cycle parameters are listed.
Figure 10. Software STORE/RECALL Cycle: E CONTROLLED
Figure 11. Software STORE/RECALL Cycle: G Controlled
NO.
Symbols
Parameter
STK17TA8-35 STK17TA8-45
Units
Notes
E Cont
G Cont
Alternate
Min
Max
Min
Max
26 t
AVAV
t
AVAV
t
RC
STORE / RECALL Initiation Cycle
Time
25
45
ns
27 t
AVEL
t
AVGL
tAS
Address Set-up Time
0
0
ns
28 t
ELEH
t
GLGH
tCW
Clock Pulse Width
20
30
ns
29 t
EHAX
t
GHAX
Address Hold Time
1
1
ns
30 t
RECALL
t
RECALL
RECALL Duration
100
100
μs
Notes
12. The software sequence is clocked on the falling edge of E controlled READs or G controlled READs
13. The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table W must be high during all six consecutive cycles.