to

About the controls on the dehumidifier.

t

•S3

<c

2i

a

S.

JS

o

o

■p

■§

.2

t:

0

1

I

§

c2

Controls

POWER Pad

Press to turn the dehumidifiei’ on and off,

HUMIDITY CONTROL Pads

Tlie humidit)’level can be set within a range

of 35% RH (Relative Humidity) to 70% RH

(Relative Humidity) in 5 % increments.

For diier air, press the ▼ pad and set to
a low’er percent value (%).

For damper air, press the ^ pad and set

to a higher percent value (%)•

When you first use the dehumidifier, set the

humidity control to 45% or 50%. ,511ow at
least 24 horn's for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a low'er settina;.

0

FAN SPEED Pad

Controls the tan speed.

Press to set to

HIGH(w LOW inn

s

Set the fan control to

HIGHior

maximum

moisture removal, \\4ien the humidity has
been reduced and quiet operation is
jji eferred, set the fan control to

LOW.

o

o

HUMIDITY LEVEL DISPLAY

Disjrlays percent humidity level.
Its accuracy is (+/- 5%).

BUCKET FULL LED

Indicates presence of bucket and its
fill level.

Other Features

4

BUCKET FULL Light

Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.

Auto Shut Off

The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
jrroper position.

j

5J

so

, when the bucket is out

of position, the unit will beep 3 times.

Auto Defrost

When frost builds up on the cooling coils,

the compressor will cycle off until the frost
disajrjrears. The fan continues to run.

Power Outage

If a power outage occurred or if the unit was

unplugged, the unit will display its prior setting.

Note:

i f

ON

is in the display, the dehumidifier is

ojterating continuously, but a specific humidity
level is not set. You will need to reset the

HUMIDITY CONTROL

t o the desired level.

Auto Restart

Once power is restored after a power outage,
the unit automatically resumes operation after
a 2 minute delay.