3-wire connection; Direct wire

Optional 3-wire connection

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer

can be moved if needed.

Strip 3V2 in. (8.9 cm) of outer covering from end of cable. Strip

insulation back 1 in. (2.5 cm). If using 3-wire cable with ground

wire, cut bare wire even with outer covering. Shape ends of wires

into a hook shape.

When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example

below.

1

.

2

.

Loosen or remove center temninal block screw.

Place the hooked end of the neutral wire (white or center wire)

of power supply cable under the center screw of terminal

block (hook facing right). Squeeze hooked end together.

Tighten screw.

3.

7. Extern^ ground connector

2. Neutral grounding wire (green/yellow)
3. Center sUver-coiored terminal block screw
4. Neutral wire (white or center wire)
5. %in. (1.9 cm) UL-iisted strain relief

Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.

f t

4, Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hoid-down screw.

Use for direct wire or power supply cord where local codes
do not permit connecting cabinet-ground conductor to
neutral wire.

1.

2

.

3.

Remove center terminal block screw.

Remove appliance ground wire (green with yellow stripes)

from external ground connector screw. Connect appliance

ground wire and the neutral wire (white or center wire) of
power supply cord/cabie under center, silver colored terminal
block screw. Tighten screw.

Connect the other wires to outer terminal block screws.

Tighten screws.

4. Tighten strain relief screws.

5. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

6. Connect a separate copper ground wire from the external

ground connector screw to an adequate ground.

7. External ground connector

2. Neutral grounding wire (green/yellow)
3. Neutral wire (white or center wire)
4. Grounding path determined by a

qualified electrician