Wire connection: power supply cord – Kenmore 8519319A User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Electrical Connection Options

If your home has:

And you will be

connecting to:

Go to Section

4-wire receptacle

(NEMA Type 14-30R)

A UL listed,

120/240 volt
minimum, 30

amp, dryer

power supply

cord*

4-wire connection:

Power supply cord

4-wire direct

A fused

4-wire connection:

_________

disconnect or

Direct Wire

circuit breaker

**" ¡Tz.7 cm) ^

box*

3-wire receptacle

(NEMA type 10-30R)

A UL listed,

120/240 volt
minimum, 30

amp., dryer

power supply

cord*

3-wire connection:

Power supply cord

3-wire direct

A fused
disconnect or
circuit breaker

box*

3-wire connection:

Direct Wire

*lf local codes do not permit the connection of a frame-grounding

conductor to the neutral wire, go to “Optional 3-wire
Connection" section.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire
connections.

7. 4-wirB rBCBptaclB (NEMA type 14-30R)

2. 4-prong plug
3. Ground prong
4. Neutral prong
5. SpadB terminals with upturned ends

6

. % in. (1.9 cm) UL approved strain relief

7. Ring terminals

1. Remove center terminal block screw.

2. Remove appliance ground wire (green with yellow stripes)

from external ground connector screw. Fasten it under center,

silver colored terminal block screw.

1. External ground connector - Dotted line shows

position of NEUTRAL ground wire before being
moved to center termini block screw

2. Center silver-colored terminal block screw
3. Green/yellow wire of harness

3. Connect ground wire (green or bare) of power supply cord to

external ground conductor screw. Tighten screw.

4. Connect neutral wire (white or center wire) of power supply

cord under center screw of the terminal block.

5.

6

.

7.

1. External ground connector

2. Green or bare copper wire of power supply cord
3.

¥4

in. (1.9 cm) UL-listed strain relief

4. Center silver-colored terminal block screw
5. Neutral grounding wire (green/yellow)

6

. Neutral wire (white or center wire)

Connect the other wires to outer terminal block screws.

Tighten screws.

Tighten strain relief screws.

Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.

Advertising