Awarning, A caution, Installation instructions – Kenmore POWER MISER 153.330551 User Manual

Page 8: Removing the old water hester

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions

Removing the Old Water Hester

Turn “OFF" the gas supply to the water heater.

AWARNING

If the main gas line shutoff serving all gas appliances is

used, also shut “OFF” the gas at each appliance. Leave all
gas appliances shut “OFF” until the water heater installa­
tion is complete.

Oisconnect the vent pipe from the draft hood where

they connect to the water heater. In mosr installations

the vent pipe can be lifted off after any screw or other

attached devices are removed. Dispose of the draft

hood. The new water heater has the draft hood which

must be used for proper operation.

©

a.

©

(Turn ' “OFF” the water to the water

heater. Some installations require that

the water be turned off to the entire

house.

©

Check again to make sure the gas supply

is “OFF to the water heater. Then dis­

connect the gas supply connection from

the gas control valve.

© Attach a hose to the water hearer drain

valve and put the other end in a floor

drain or outdoors. Open the water heater

drain valve. Open a nearby hot water

faucet which will relieve pressure in the

water heater and speed draining.

If you have copper piping to the water

heater, the two copper water pipes can

be cut with a hacksaw approximately 4"

away from where they connect to the

water heater. This will avoid cutting off

the pipes too short. Additional cuts can

be made later if necessary. Disconnect

the temperature-pressure relief valve

drain line. When the water heater is

drained, disconnect the hose from the

drain valve. Close the drain valve. The

water heater is now completely discon­

nected and ready to be removed.

©

If you have galvanized pipe to the water

heater, loosen the two galvanized pipes

with a pipe wrench at the union in each

line. Also disconnect the piping remain­

ing to the water heater. These pieces

should be saved since they may be need­

ed when reconnecting the new water

heater. Disconnect the temperature-pres­

sure relief valve drain line. When the

water heater is drained, disconnect the

hose from the drain valve. Close the

drain valve. The water heater is now

completely disconnected and ready to be

removed.

AWARNING

The water passing out of the drain valve may be extremely
hot. To avoid being scalded, make sure all connections are

tight and that the water flow is directed away from any
person.

A CAUTION

Mineral buildup or sediment may have accumulated in the

old vrater heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining.

Advertising
This manual is related to the following products: