American Flame Gas Control System Error Codes

Ignition Safety: Protection for Ignition System
Error Code: One beep every one second
Description of Fault: Warn users if the pilot is not successfully ignited in 60 seconds.
How to Clear: Press OFF then ON buttons to re-attempt ignition.
What to Check:

•

Ensure gas supply is turned on.

•

Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.

•

Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.

•

Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.

•

Verify that the black ground lead form the module is connected to a proper ground on the fireplace.

•

Ensure there is no blockage in the pilot line.

Sensor Safety: Protection for Flame Sensor
Error Code: 4 beeps every one second
Description of Fault: Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence
is initiated. This fault will also occur if pilot flame sensor is shorted to ground.
How to Clear: Press OFF then ON buttons to re-attempt normal ignition.
What to Check:

•

Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).

•

Replace pilot assembly.

•

Replace module.

Thermal Safety: Overheat Protection
Error Code: 4 beeps every two seconds.
Description of Fault: Warn users that the module’s internal temperature has exceeded 170° F (77° C).
How to Clear: Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.
What to Check:

•

Is module located in unapproved location, too close to burner?

•

Move to cooler location.

Communication Safety: (NOTE: This feature is only available when transmitter includes an LCD screen).
Error Code: One beep every four seconds.
Description of Fault: Warn users that the transmitter and receiver are not communicating properly.
What to Check:

•

Verify batteries in both transmitter and receiver are new.

•

Ensure transmitter is located within 20 feet (6 m) of receiver.

•

Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere
with transmission.