Touch panel controls, Vent control, Brightness adjust feature (some models) – Kenmore 70089 User Manual

Page 20: Controls, Dbbbibb

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Controls

Figure 37.

Touch Control Panel

m

. -

m

(

off

)

SMARf

SET

LOW

COOL

MED

COOL

HIGH

COOL

power

),

' ^ l l

ÍDELAY)
(sTARTj

■DBBBIBB

.

MODE

SET

EXHAUST CLOSED

See Figure 37. Kenmore room air conditioners have an
electronic touch control panel located across top front of
unit. Functions and operation of each control are
explained below.

Touch Panel Controls

To operate touch controls, press control pad until

indicator above pad lights (does not apply to OFF or

VIA P^ds).

OFF

—Turns air conditioner off.

SMART SET

—Places air conditioner in "smart” cooling

mode. SMART SET uses computer logic to cool area

quickly and quietly. When unit first turns on, fan starts at

high speed. As room temperature nears set

temperature, fan automatically switches to medium

speed, then low speed. When room cools to set

temperature, fan continues to run at tow speed and

compressor cycles on and off to maintain room

temperature.

LOW COOL—

Fan operates continuously at low speed,

except in power saver mode. If unit is in a cooling mode,
compressor cycles on and off as required to maintain
set temperature. Select this setting for quietest
operation.

MED COOL—

Fan operates continuously at medium

speed, except in power saver mode. If unit is in a
cooling mode, compressor cycles on and off as required
to maintain set temperature. Select this setting for

reduced air circulation and quieter operation.

HIGH COOL

—Fan operates continuously at high speed,

except in power saver mode. If unit is in a cooling mode,
compressor cycles on and off as required to maintain
set temperature. Use this setting for maximum air
circulation and faster cool-down during initial start up.

POWER SAVER PLUS

—Places air conditioner in

energy-saving mode. Energy-saving mode works in
conjunction with SMART SET mode and low, medium,
or high fan speeds. In energy-saving mode, air
conditioner maintains room temperature within 1.5° F of
programmed temperature setting. When POWER
SAVER PLUS is selected, fan cycles on and off with
compressor, instead of running continuously as in other
modes. During compressor off cycle, fan automatically
turns on for about 2 minutes at 5 minute intenrals to
sample room air temperature. If room temperature is
within 1.5°F of programmed temperature, time between

sampling increases to a maximum of 15 minutes.

It room temperature is more than 1,5°F above

programmed setting, fan continues to run and
compressor cycles on to coot room. When room cools
to set temperature, compressor and fan turn off and
time between air sampling cycles decreases to a

minimum of 5 minutes.

FAN ONLY

—Fan operates continuously at set speed

(high, medium, or low) and compressor remains off..
Use this setting to circulate air without cooling and, with

VENT CONTROL in EXHAUST position, to vent room

of stale air, odors, smoke, etc. Displays actual room

temperature.

V I A — d e c r e a s e (“down” arrow) or increase

(“up" arrow) set temperature. When used with DELAY
START function, arrow keys adjust delay start or stop
time.

DELAY START

—^Allows programming a delay of up to

24 hours before air conditioner starts, or programming
air conditioner to automatically stop after up to 24 hours
of operation. Automatic start or stop is programmable
from 1 hour (minimum) up to 24 hours (maximum), in
one hour increments. See Operation Instructions for

information on programming air conditioner for delay

start or automatic stop.

Vent Control

Vent control lever, located on lower right corner of front

panel, controls a damper that recirculates or exhausts
room air.

With control in CLOSED position, damper is closed and

air in area being cooled is recirculated through air
conditioner, filtered, cooled, and returned to room. No air
is exhausted (vented) outside.

NOTE:

For maximum efficiency and cooling, vent

control should remain closed any time air

conditioner is cooling.

With control in EXHAUST position, damper is open.
When open, room air is exhausted (vented) outside.

Use exhaust position to remove stale or smoky air.

NOTE:

To conserve energy, use FAN ONLY position

with EXHAUST feature.

Brightness Adjust Feature (some models)

Display brightness can be changed using V | A

To decrease brightness, simultaneously press and hold

OFF pad with “down" arrow. To increase brightness,
press and hold OFF pad with “up" arrow key.