MAINTENANCE INSTRUCTIONS

TROUBLE-SHOOTING GUIDE

WARNING!

IF UNIT GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT

POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!

If hot unit is NOT working, first check the following causes:

1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is

blown.

3. Switch is turned off.
4. Thermostat is turned off, or is set too

low.

PROBLEM POSSIBLE

CAUSE

SOLUTION

Humidity is low

1. Water in pan may be low
2. Thermostat set too low

1. Add water
2. Turn up thermostat

Cabinet does not heat, or
doesn’t heat properly

1. Thermostat
2. Heater relay
3. Loose wiring at heater relay
4. Hi-limit switch
5. On/Off switch

1. Replace
2. Replace
3. Replace
4. Replace
5. Replace

Blowers do not operate

1. On/Off Switch
2. Blower
3. Control

1. Replace
2. Replace
3. Replace

Heater will not shut off 1.

Thermostat

2. Relay

1. Replace
2. Replace

Vent fan does not shut off 1. Vent fan switch defective

2. Control compartment still hot

1. Replace
2. Wait until it cools
Check “Heaters will not shutoff

Vent fan does not operate

{See NOTE}

1. Vent fan switch defective
1. Vent fan defective

1. Replace
2. Replace


NOTE:

Vent fans will not operate until the control compartment requires ventilation to limit

temperatures. Replacement of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service
centers. Instructions for replacing parts are included in replacement parts list.