TROUBLESHOOTING


Problem

Possible Cause

Solution

Full-time surge protection
outlets stop providing
power to equipment.

Circuit breaker has tripped
due to an overload.


Turn the UPS off and unplug at least one piece of
equipment. Wait 10 seconds, reset the circuit
breaker by depressing the button, and then turn the
UPS on.

Battery not fully charged.

Recharge the battery by leaving the UPS plugged
in.

The UPS does not
perform expected runtime.

Battery is slightly worn
out.

Contact CyberPower Systems about replacement
batteries at

[email protected]

The on/off switch is
designed to prevent
damage by rapidly turning
it off and on.

Turn the UPS off. Wait 10 seconds and then turn
the UPS on.

The unit is not connected
to an AC outlet.

The unit must be connected to a 110/120v 60Hz
outlet.

The battery is worn out.

Contact CyberPower Systems about replacement
batteries at

[email protected]

The UPS will not turn on.



Mechanical problem.

Contact CyberPower Systems at

[email protected]

The serial cable is not
connected.

Connect the serial cable to the UPS unit and an
open serial port on the back of the computer. You
must use the cable that came with the unit.

The serial cable is
connected to the wrong
port.

Check the back of the computer for an additional
serial port. Move the cable to this port.

The unit is not providing
battery power.

Shutdown your computer and turn the UPS off.
Wait 10 seconds and turn the UPS back on. This
should reset the unit.

PowerPanel™ is inactive
(all icons are gray).

The serial cable is not the
cable that was included
with the UPS unit.

You must use the serial cable that was enclosed
with the unit for the software and unit to be able to
communicate.


SPECIFICATIONS


CPS320SL CPS375SL CPS500SL CPS575SL CPS650SL

Capacity

320VA

(185W)

375VA

(210W)

500VA

(275W)

575VA

(320W)

650VA

(350W)

Input Voltage on Utility

100V to 140V

Input Frequency

57 Hz to 63 Hz

On-Battery Output Voltage

120Vac ± 5%

Transfer Time

4ms Typical

Max. Load for UPS Outlets
(3 Outlets)

320VA

(185W)

375VA

(210W)

500VA

(275W)

575VA

(320W)

650VA

(350W)

Max. Load for Full-Time Surge
Protection outlets (6 Outlets)

12 Amps

On-Battery Output Wave Form

Simulated Sine Wave Form

Operating Temperature

+ 32°F to 95° F. (0° C to 35° C)

Operating Relative Humidity

0 to 95% NON-CONDENSING

Size (Length x Width x Height)

9 7/8” x 6 3/16” x 3 1/8” (25.8cm x 15.9cm x 8.3cm)

Net Weight

10lbs.

10 lbs.

13

13 lbs.

14 lbs.

Typical Battery Recharge Time

8 hours typical from total discharge

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Battery Type

12V / 3AH

12V / 4AH

12V / 7AH

12V / 7.2AH

12V / 7.5AH

Recommended Battery

Spill-proof, Maintenance-free, sealed lead-acid

Safety Approvals

UL1778(UPS), CUL107.1/FCC/DoC Class B

8