Chapter 14 - General

219

Chapter 14 - General

Physical RS-232 Configuration: WAN Dialog
Box

Physical RS-232 Configuration: WAN Dialog Box

To access this dialog box, select WAN/Physical Configuration from the
Device View.

>

Async/Sync

This set of radio buttons determines whether this interface will use the asyn-
chronous or synchronous mode of communication.

If Async is selected, the interface will communicate asynchronously
(using start and stop bits) with the device it is connected to. This mode
of communication is typically used by modems.

If Sync is selected, the interface will communicate synchronously (using
a separate clock) with the device it is connected to. This mode of commu-
nication is typically used by CSU/DSU’s and ISDN Terminal Adapters.

v Note: Interfaces set for asynchronous operation do not use parity, and use
one stop bit.

v Note: Some high-speed WAN interfaces (i.e. V.35) may only support
synchronous communications. This set of radio buttons will not appear in the
CompatiView Physical Configuration: WAN Dialog Box for these interfaces.