CONNECTION OF FM-430 CONNECTIORS

6.3 OPTIONAL FM-430 INSTALLATION

1. Remove the transceiver top covers and unplug

the speaker lead.

2. Mount the FM-430 on the top right side of the trans­

ceiver with 6 screws.

3. Connect the FM-430 harness to the transceiver as fol­

lows:

*

Connect the leads from connector (1) to connector

(19) of the Switch unit (X41 -1470-00).

*

Connect the leads from connector (3) to connector

(24) of the IF unit (X48-1370-00).

* Arrange the leads from connectors (2) and (4) on the

bottom of the transceiver to pass along the side of the

Switch unit. Connect the leads from connector (2) to

connector (20) of the RF unit (X44-1510-00). Con­

nect the leads from connector (4) to connector (6) of

the RF unit.

4. Tie the leads as illustrated using the supplied vinyl ties.

5. Reinstall the bottom cover, reconnect the speaker lead,

and reinstall the top cover.

FM-430

connector No.

Unit and TS-430 connector No.

(1)

Switch unit (X41 -1470-00)....................... 19

(2)

RF unit (X44-1 510-00).............................20

(3)

IF unit (X48-1370-00)............................... 24

(4)

RF unit (X44-1 510-00)............................. 6

TS-430 top view

Switch unit

TS-430 bottom view

Fig. 6-5 FM-430 Installation