S-Meter Squelch

By activating S-meter Squelch, you can set the
squelch threshold so the squelch does not open until

a signal with the same or greater strength than the S-
meter setting is received.

1 Press [F] (1 s) to enter Menu A.

2 Select "S.SQL" {page 22}.

• The current S-meter Squelch status appears.

n

c c

t tj tj O

\ \ 1 / /

/ / n \

/ / M \ “«f

1 S • 7 • OVCR

3 Select a squelch status.

• OFF: Disables S-meter Squelch.

• ON: Enables S-meter Squelch.

• Default: OFF

4 Exit Menu A.

• "S.SQL" remains ON.

5 After switching S-meter Squelch ON, adjust the

SQL control to set the S-meter for the minimum
signal strength that you want to open the squelch.

SQUELCH HANG TIME

When using S-meter Squelch, you may want to adjust
the Hang Time (time for the squelch to close after the

received carrier drops).

1 Press [REV] + POWER ON to enter Menu B.

2 Select Menu No. 64 (page 24}.

• The current Hang Time value appears.

3 Select a value.

• The available selections are OFF, 125, 250,

500 ms.

• Default: OFF.

4 Exit Menu B.

29