Operating instructions and parts manual – Campbell Hausfeld PW4035 User Manual

Page 12

Advertising
background image

12

Operating Instructions and Parts Manual

www.chpower.com

troubleshooting Chart - Gasoline Powered Pressure Washers Only

Symptom

Possible Cause(s)

Corrective Action

Engine will not start or
is hard to start

1 . No gasoline in fuel tank or

carburetor

2 . Low oil
3 . Start/Stop switch in stop position
4 . Water in gasoline or old fuel
5 . Dirty air cleaner filter
6 . Spark plug dirty, wrong gap or

wrong type

7 . Spray gun closed
8 . Other causes

1 . Fill the tank with gasoline,open fuel shut off valve .

Check fuel line and carburetor

2 . Check oil level . Fill if necessary
3 . Move switch to start position
4. Drain fuel tank and carburetor. Use new fuel and dry

spark plug

5 . Remove and clean or replace
6 . Clean, adjust the gap, or replace
7 . Trigger spray gun
8 . See engine owner’s manual

Engine misses or lacks
power

1 . Partially plugged air cleaner filter
2 . Spark plug dirty, wrong gap or

wrong type

1 . Remove and clean or replace
2 . Clean, adjust the gap, or replace

Low pressure and/or
pump runs rough

1 . Worn or wrong size tip
2 . Inlet filter on pump clogged
3 . Worn water seals, abrasives in

water, or natural wear

4 . Fouled or dirty inlet or discharge

valves

5 . Restricted inlet

6 . Worn inlet or discharge valves
7 . Leaking high pressure hose
8 . Pump drawing in air
9. Unloader valve seat faulty or worn

1 . Replace with tip of proper size
2 . Clean . Check more frequently
3 . Check filter . Replace water seals . See service center

4 . Clean inlet and discharge valve assemblies . Check
filter
5 . Check garden hose, may be collapsed or kinked .
Check inlet water flow
6 . Replace worn valves
7 . Replace high pressure hose
8 . Ensure hoses and fittings are tight
9 . Check and replace

Water leakage from
under pump manifold

Worn water seals

Install new water seals . See service center

Water in pump
crankcase (milky oil)

1 . Humid air condensing inside

crankcase

2 . Oil seals leaking

1 . Change oil as specified in maintenance schedule
2 . Install new oil seals . See service center

Frequent or premature
failure of the pump
water seals

1 . Scored damaged or worn plungers
2 . Abrasive material in the fluid
3 . Inlet water temperature too high
4 . Overpressurizing pump
5. Excessive pressure due to partially

plugged or damaged tip

6 . Pump running too long without

spraying

7 . Pump running dry

1 . Install new plungers . See service center
2 . Install proper filtration on pump inlet plumbing
3. Check water temperature; may not exceed 100o F.
4 . Do not modify any factory set adjustments .
5 . Clean or replace tip .

6 . Never run pump more than 2 minutes without

spraying

7 . Do not run pump without water

Strong surging at the
inlet and low pressure

Foreign particles in the inlet or
discharge valve or worn inlet and/or
discharge valves

Clean or replace valves . See service center

Oil leakage between the
engine and the pump

Worn oil seals and/or o-ring

Replace oil seals and/or o-ring . See service center

Fluctuating pressure

1 . Valve worn, dirty or stuck
2 . Pump drawing in air
3 . Tip clogged

1 . Check and replace
2 . Ensure hoses and fittings are tight . Purge air from

garden hose

3 . Check or replace

Pressure drops after
period of normal use

1 . Worn pump water seals
2 . Nozzle worn
3 . Valve worn, dirty or stuck
4. Unloader valve seat worn or dirty
5 . Nozzle in low psi position

1 . Check and replace
2 . Check and replace
3 . Check, clean or replace
4 . Check, clean or replace
5 . Pull back nozzle to high pressure position

Advertising
This manual is related to the following products: