Port - embedded installation, Building the serial ribbon cable – Comtrol Hub DeviceMaster User Manual

Page 18

Advertising
background image

18 - Hardware Installation

DeviceMaster Installation and Configuration Guide: 2000594 Rev. A

Hardware Installation

1-Port - Embedded Installation

Installing the DeviceMaster 1-Port Embedded system follows these basic steps:

•

Building the serial ribbon cable (below).

•

Mounting the Embedded

on Page 19 and installing light pipes.

•

Attaching the Network and Serial Cables

on Page 20.

•

Connecting the Power and Verifying Installation

on Page 20.

Observe proper ESD techniques when handling the DeviceMaster.

Building the Serial
Ribbon Cable

Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 1-Port Embedded IDC10 connector (J3).

Caution

J3 Header RS-232

RS-422

RS-485

1

CD

Not used Not used

2

DSR

Not used Not used

3

RxD

RxD-

Not used

4

RTS

TxD+

TRX+

5

TxD

TxD-

TRX-

6

CTS

RxD+

Not used

7

DTR

Not used Not used

8

RI

Not used Not used

9

GND

Not used Not used

10

Not connected

Pin 1

Pin 6

1 2

9 10

Ribbon Cable

10-Pin
Socket

Pin 5

Pin 9

DB9
Male

J3

Advertising