Serial terminals (4) - 1e, Serial terminal (4) connectors – Comtrol UP DeviceMaster Installation User Manual

Page 47

Advertising
background image

Hardware Installation and Configuration Guide: 2000451 Rev. J

Connecting Serial Devices - 47

Connecting Serial Devices

Serial Terminals (4) - 1E

This subsection discusses the following topics for the DeviceMaster UP 2-port 1E
with serial terminals (4). See

Serial Terminals (8) - 2E

on Page 49 if the

DeviceMaster UP has eight serial terminals.

•

Serial Terminal (4) Connectors

on Page 47

•

Serial Terminal (4) Null-Modem Cables (RS-232)

on Page 48

•

Serial Terminal (4) Null-Modem Cables (RS-422)

on Page 48

•

Serial Terminal (4) Straight-Through Cables (RS-232/485)

on Page 48

•

Serial Terminal (4) Loopback Signals

on Page 49

•

Connecting Serial Devices

on Page 49

Serial Terminal (4)
Connectors

Use the following table or drawings for signal information. The signals for
SERIAL2 are the same as SERIAL1.

RS-232†

TxD

RTS

RxD

CTS

RS-422/RS-485

Full-Duplex

TxD-

TxD+

RxD-

RxD+

RS-485

Half-Duplex

TRxD-

TRxD+

† RS-232 ground must be connected to the appropriate signal ground

terminal.

CTS

RxD

RTS

TxD

RS-232

†

RxD+

RxD-

TxD+

TxD-

RS-422

RS-485 Full-Duplex

TRxD+

TRxD-

RS-485 Half-Duplex

† RS-232 ground must be connected to the appropriate signal ground

† Wire gauge: AWG 12-22

Signal
Ground

Not connected

Positive†

Return†

5-30VDC

Signal
Ground†

Chassis
Ground†

RS-232: Connecting the Ground

Advertising