Comtrol UP DeviceMaster Filtering and Data Extraction User Manual

Page 8

Advertising
background image

8 - DeviceMaster UP Filtering and Data Extraction Reference Guide: 2000470 Rev. B

Chapter 2. Data Extraction/Filtering Process

Filtering Criteria Definition

•

The possible filtering criteria parameters for barcode filtering are Numbering, Company code, and
Product code.

•

String filtering has no applicable filtering criteria. All serial/socket bytes are treated as raw data and
compared in the filtering process.

Example:

•

A DeviceMaster UP is connected to an RFID reader.

•

The PLC interface is enabled and is operating in RFID filtering mode. The PLC filtering criteria is set to
Company code and Product/Location code.

•

The application port is enabled and it is also operating in RFID filtering mode. The application filtering
criteria is set to Company code, Product/Location code, and Serial Number.

•

Six RFID tags are then read at one time. All have the same Company and Product/Location codes, but
different Serial Numbers.

-

The PLC will receive one RFID tag because all have the same Company and Product/Location codes.

-

The application will receive all six RFID tags because the Serial Number is included in the filtering
criteria and all six tags have unique serial numbers.