Test 2, Test 3, Test 2 test 3 – Comtrol Multiport Modems Windows 98 User Manual

Page 37

Advertising
background image

Comtrol Tools

37

Test 2

3.

Enter atz. This should return an OK.


If you do not see atz on the screen, type ate1 and press the Enter key, then type
atz and press the Enter key again. If the screen displays atz and OK, proceed. If
it does not, contact

Technical Support

.

4.

Enter at&f&w0&w1 to restore the original factory settings for the selected
port.

Note: This command does not work on RocketModem II. Enter at&f for

RocketModem II.

5.

Select Port > Open Port > COMx +1.

a.

Repeat steps 1 through 4.

6.

Repeat step 5 for all remaining ports.

7.

Enter at&v. This should display the modem configuration.

Test 2

The following test initiates a call from the modem to an ordinary telephone.

1.

Connect the modem to a phone line.

2.

Enter atdtphonenumber.

Where phonenumber is the phone number of an ordinary telephone.

If the telephone is near you, you should hear it ring.

3.

Enter +++ath to hang up.

Test 3

The following test initiates a call from one modem to another modem.

1.

Connect two modems to phone lines.

2.

Open two Test Terminal sessions.

3.

Select Windows > Tile to display both Test Terminal sessions side by side.

4.

Enter atdtphonenumberofdestinationcomx in the screen for the first modem.

Where phonenumberofdestinationcomx is the phone number for the second
modem.

The screen for the second modem should display RING.

5.

Enter ATA in the screen of the second modem. The modem should answer.

6.

Check the connection speed.

7.

Send typed characters from one modem to the other. The text should appear in
the screen for the modem you are sending the text to. If data is transferred,
the test is complete.

8.

Enter +++ath to hang up.