Troubleshooting

3.1. Resolving Installation Problems

If installation fails or you are trying to resolve a problem, you should try the
following before calling the Comtrol technical support line:
•

Check the signals between your peripherals and the interface box to verify
that they match (if applicable). See the appropriate Hardware Reference
Card
for information.

•

Check to make sure the serial and interface cables are connected properly.

•

Check to see if the

DIP

switch is set to the desired address by checking the

/ROCKET/INSTALL.LOG file with an editor against the settings on each
controller.

•

Reseat the controller in the slot.

•

Make sure that the expansion slot screw was replaced after inserting the
controller.

•

Reinstall the

API

, selecting a different

I/O

address range for the controller.

For possible

I/O

address conflicts, see Tables 3-1 and 3-2.

Table 3-1 defines the 64-byte

I/O

address blocks from 0 through 3FFh and their

known uses. Table 3-2 defines the 64-byte

I/O

address blocks from 400 through

FFFh and their known uses.

Table 3-1. System

I/O

Addresses – Up to 3FF

Address

Block

Addresses

Used

Description

000 – 03F

Reserved for Motherboard

040 – 07F

Reserved for Motherboard

080 – 0BF

Reserved for Motherboard

0C0 – 0FF

Reserved for Motherboard

100 – 13F

140 – 17F

180 – 1BF

1C0 – 1FF

1F0 – 1F8

Fixed Disk

200 – 23F

240 – 27F

278 – 27F

LPT2, IDE

controllers,

multifunction boards (game

ports)

280 – 2BF

2C0 – 2FF

2E8 – 2EF
2F8 – 2FF

COM4
COM2

300 – 33F

340 – 37F

378 – 37F

LPT1

380 – 3BF

3B0 – 3BF

Monochrome Display and

LPT3

3C0 – 3FF

3D0 – 3DF
3E8 – 3EF
3F0 – 3F7
3F8 – 3FF

Graphics Monitor Adapter

COM3

Floppy Disk Controller

COM1

Table 3-2. System I/O Address Aliases – Above 3FF

Address

Block

1st Alias

2nd Alias

3rd Alias

000 – 03F

400 – 43F

800 – 83F

C00 – C3F

040 – 07F

440 – 47F

840 – 87F

C40 – C7F

080 – 0BF

480 – 4BF

880 – 8BF

C80 – CBF

0C0 – 0FF

4C0 – 4FF

8C0 – 8FF

CC0 – CFF

100 – 13F

500 – 53F

900 – 93F

D00 – D3F

140 – 17F

540 – 57F

940 – 97F

D40 – D7F

180 – 1BF

580 – 5BF

980 – 9BF

D80 – DBF

Table 3-1. System

I/O

Addresses – Up to 3FF(Continued)

Address

Block

Addresses

Used

Description

Section 3. Troubleshooting

Advertising