Electromagnetic compliances, Other specification information – Comtrol DM Primo User Manual

Page 11

Advertising
background image

DeviceMaster Primo Hardware Installation

11

Electromagnetic Compliances

Electromagnetic
Compliances

This table illustrates electromagnetic compliances for the Primo.

Other Specification
Information

This table provides other data that you may require about the Primo.

Electromagnetic Compliances

Status

EMC: (conforms to the following standards)

FCC Class B
EN55022: 1994 class B
EN61000-3-2: 1995 class B
EN61000-3-3: 1995
EN55082-1: 1997
EN61000-4-2: 1995

Contact Discharge 4kV, Air Discharge 8kV

EN61000-4-3: 1995
EN61000-4-4: 1995

AC/DC Power supply 1kV, Data/Signal lines 5kV

EN61000-4-5: 1995

AC/DC Line to Line 1kV, AC/DC Line to Earth 2kV

EN61000-4-6: 1995
EN61000-4-8: 1993

3A/m at 50Hz

EN61000-4-11: 1994

Yes

Safety:

EN60950
UL/CUL, TUV

Yes
Yes

Topic

Specification

External power supply adapter (if

provided):
Input line frequency
Input line voltage
Output voltage
Output current

Note: Any power source that

meets the output voltage
and current requirements
can be used.

See illustration at left.

60 Hz
100 - 120VAC
12 VDC
400 mA (minimum)

Processor type

x186 or equivalent

Memory

512 KB

Baud rate/port range

50 bps - 230 Kbps

Ethernet host interface

(upstream and downstream)

10/100Base-T (10/100 Mbps - RJ45)

Serial interface

RS-232, RS-422, and RS-485,
Dip Switch Selectable

Network protocols

TCP, UDP, ICMP, Telnet, IP,

RTelnet, DHCP

Configuration:

Data bits
Parity
Stop bits

7 or 8

Odd, Even, None

1 or 2 (with parity setting of None)

SNMP support

Monitoring only.

Power Connector

-

+

VDC

Advertising