E-34

Troubleshooting

The status of the indicators lets you know the current operational status of the projector. This
section provides details about indicators.

z “POWER” in the following table stands for the “POWER/STANDBY” indicator.

Normal Operation Indicators

Error Indicators and Warning Messages

When an error occurs, wait until cool down is complete and the fan stops before unplugging the
AC power cord. If you unplug the AC power cord while the fan is still operating, an error may
occur when you plug the AC power cord back in.

Indicators

When this indicator:

Is this:

It means this:

POWER :

Amber steady

You have just plugged the AC power cord into a power
outlet. Wait until the projector enters the standby state
(see below) before trying to turn on power.

TEMP :

Amber steady

LAMP :

Amber steady

POWER :

Amber steady

Standby state: The AC power cord is plugged in and
the projector is in standby.

POWER :

Green flashing

Projector is warming up after being turned on.

POWER :

Green steady

Projector is on and standing by for use.

POWER :

Amber flashing

Projector is cooling down after being turned off. If the
projector is hot when you plug the AC power cord into
a power outlet, it also goes into a cool down state.

LAMP :

Green steady

The projector’s Eco Mode is turned on.

Indicator/Error Message

Description and Required Action

POWER
TEMP
LAMP

: Green steady
: –
: –

The projector’s internal temperature is very high. Press the
[ESC] key to clear the warning message and perform the
following steps.
1 Check for any blocking of the projector’s intake vents and

exhaust vents, and make sure that there is sufficient space
around the projector. See

Setup Precautions” (page E-15).

2 If there is dust accumulated around the intake vents and/or

exhaust vents, turn off the projector and remove it. See

Cleaning the Projector” (page E-27).

Message : Internal temperature

is too high. Check
projector air vents for
blockage.

LAMP indicator

POWER/STANDBY indicator

TEMP indicator