Digilent 6003-210-012P User Manual

Page 7

Advertising
background image

4

3.

The 5 buttons are pulled to GND through a 10K resistor and pulled up to 2.5 V when pressed. When not

pressed the button is pulled up to 2.5V. A series resister (10K Ohms) bleeds off excess voltage if the

FPGA is programmed to an IO standard below 2.5V. These are marked BTN0-4.

Figure 4. Schematic for Buttons

Signal Name

Pin

Voltage

Description

Button 0

H14

2.5V

Center

Voltage must be sufficient to

cross the “on” threshold –

need to verify, as this might

be changed from “any” to >=

some voltage.

Button 1

G15

2.5V

West

Button 2

G18

2.5V

North

Button 3

H13

2.5V

East

Button 4

G12

2.5V

South

Table 3. Button FMC Connections

4.

Then there are 5 LED's co-located with the buttons (BTN0-BTN4) in a Rosetta pattern. Each LED is pulled

to GND via a 300 Ohm resistor. The schematics are show in (2) Linear LEDs

Signal Name

Pin

Voltage

Description

LED Rosetta 0

H16

any

Center

Voltage must be sufficient to

cross the “on” threshold –

need to verify, as this might

be changed from “any” to >=

some voltage.

Advertising