Analog inputs and v – Digilent 410-217P User Manual
Page 2

PmodAD2 Reference Manual
www.digilentinc.com
page 2 of 2
Copyright Digilent, Inc. All rights reserved. Other product and company names mentioned may be trademarks of their respective owners.
Analog Inputs and V
Ref
The PmodAD2 allows for up to four analog
inputs, VIN1 – VIN4. To use the input VIN4,
the jumper JP1 must be set to V4.
The configuration register has a REF_SEL bit
that, when enabled, allows a voltage other than
the supply voltage to be used as the reference.
If REF_SEL is enabled, and if JP1 is set to
REF, V
Ref
from the on-board voltage reference
generator is 2.048V. If JP1 is set to V4, V
Ref
is
the voltage at input VIN4.
Connector J2 – Analog Input
Pin
Signal
Description
1
VIN1
Analog Input 1
2
VIN2
Analog Input 2
3
VIN3
Analog Input 3
4
VIN4
Analog Input 4
5
GND
Power Supply Ground
6
VCC
Power Supply (3.3V)