13 b. electric starter starting – DLE 40 User Manual

Page 13

Advertising
background image

13

B. Electric Starter Starting

1. A 24 volt electric starter is recommended to start the DLE-40.

Make sure you use a high quality, lightweight aluminum spinner.

2. Have someone help you hold the airplane while you start it.

3. Close the choke on the carburetor and open the throttle slightly

from the idle position.

4. Switch on, or power your radio system and make sure you have

control of the throttle visually at the carburetor. Also make sure that
the reversing position of the servo is correct at the transmitter and
that the throttle is at the minimum position.

5. Switch the ignition to ON. If you installed the optional TX activated

gas engine kill switch (DLEG9205) properly between the on/off

switch and the ignition make sure that the TX switch assigned is in
the on position. The LED should be illuminated red to indicate that
the ignition is armed.

6. Using the starter, turn over the engine till popping sound is heard.

Next, open the choke.

7. Use your electric starter to turn over the engine until it starts.

8. After starting, let the engine idle for one to two minutes. Open and
close the throttle slowly until the engine runs smoothly at idle and

at full throttle. Acceleration should also be smooth. If acceleration
is not smooth, adjustments to the carburetor may be necessary.

(See Adjustment of the Engine on pages 10–12.)

9. If your engine does not start, repeat steps 6 and 7.