4.4 Connection screen
No.
Conn.
Designation
Colour
Function / assignment
CON10 L
black
Power supply 230 VAC, 50-60 Hz, for voltage range refer to rating plate
CON11 N
blue
Neutral conductor
CON12 PE
green/
yellow
Protective earth
1
GND
blue
GND - Connection for control interface
2
0- 10V PWM
yellow
Control input 0 - 10 V or PWM, electrically isolated
3
10V/ max 1.1mA red
Voltage output 10 V / 1.1 mA, electrically isolated, not short-circuit-proof, Isink = 10 mA
4
Tach
white
Tach output: open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA
Item no. 51539-5-9970 · ENG · Revision 84194 · Release 2015-01-09 · Page 8 / 11