3.4 Setting DIP Switch

(Only serial interface type)

DIP switch is provided only for serial interface specification.
The DIP switch is located at the bottom of the paper holder. To set the DIP
switch open the printer cover and remove the paper.

Baud Rate (bps)

Switch No.

Function

ON

OFF

FEED

FEED

ON

1

8

OFF

Baud rate selection

See Table below.

Initial

Settings

1

Communication condition DIP switch setting

Internal memory

ON

setting method

setting

2

Hand shake

XON/XOFF

DTR/DSR

OFF

3

Bit length

7 bits

8 bits

OFF

4

Parity check

With parity

None

OFF

5

Parity selection

Even parity

Odd parity

OFF

6

OFF

7

ON

8

Reserved

Fixed

OFF

Selecting baud rate

Switch No.

6

7

2400

OFF

OFF

4800

ON

OFF

9600

OFF

ON

19200

ON

ON

1200 bps and 38400 bps can also be selected by a command or the memory
switch. 9600bps is factory setting.