Ecler CA120 User Manual

Page 9

Advertising
background image

9

Notes:

1. If the device is in special mode for 10 seconds and the front knob is not touched, the

equipment automatically reverts to VOL/MUTE mode.

2. In tone control mode, when you turn the knob in either direction it flashes fast while the

gain of the affected tone increases. When either end of the scale is reached (-10 ó
+10dB) or when it goes through the centre point (0dB) it flashes more slowly.


4.3. AUTO STANDBY Function


The

AUTO STANDBY function (idle or low consumption mode) means you can install the

CA120 in inaccessible places and leave the device connected to the mains power supply
permanently because when no signal is detected, it automatically goes into standby mode, saving
energy.

To

enable

AUTO STANDBY use the micro switch with the same name on the rear panel of

the unit (see section 7. DIAGRAM OF FUNCTIONS). When activated, if there is no audio signal in
any of the inputs (or the signal is very weak, below the activation threshold), the CA120 automatically
goes into STANDBY mode, and the ON/STBY on the front panel of the device goes orange. When a
valid audio signal is detected in any of the inputs, the CA120 leaves standby mode and starts
operating normally again and the ON/STBY LED goes green.

When you enable AUTO STANDBY mode with the micro switch (position ON) one of two

things happens:

a) There is NO audio signal in the inputs. Result: the amplifier immediately goes into

AUTO STANDBY mode

b) There is an audio signal in the inputs. Result: the amplifier stays active

When the amplifier goes into AUTO STANDBY mode, all the LED indicators go out with

the exception of ON/STBY. If the amplifier is in STANDBY mode and you turn the VOL/MUTE
knob to adjust the volume or activate the MUTE function, the LED lights will come on for a short
time then go out again. Remember that the first acting on the VOL/MUTE knob, this will only reset
the LED indicators, and will not change any of the settings.


When the unit is a special mode (source selection or setting adjustment) the LED

indicators will not go out even if the amplifier is in AUTO STANDBY mode.


4.4. LED indicators

SP: The signal presence or SP LED indicator shows that there is a signal in the
amplifier input. This lights up when the input level reaches the established
detection threshold.

CLIP: The saturation or CLlP LED indicator comes on when the signal delivered to
the speakers is close to the amplifier's clipping or saturation level. Input signals
should be set to ensure the CLIP (saturation or cut off) indicators never stay on,
but that they do so at most to the beat of the lowest sound frequencies. Otherwise
the amplified signal will be distorted with low quality and low intelligibility.

Note: If the input signal is too high, the CLIP indicator lighting up very

frequently over a short time interval (a few seconds), the amplifier may go into
protection mode, being muted to return to normal operation in a short time


MUTE: This lights up when the MUTE function is active (silent mode)

Advertising