Changing the Blade:

Inspect the new blade thoroughly before installing. Check for cracks, worn or out-of-round arbor holes. Refer to the

Rx for Diamond Blades pamphlet provided with your blade for more detailed information on inspecting blades. Be sure
the blade is appropriate for the job and matches the arbor speed and mounting configuration on this saw. (See page 7)

The TMS-10 was designed to be used with diamond saw blades

Step One:
Remove power plug from power source.
Pull the rolling table all the way to the front of the machine.
Adjust and lock the blade/blade guard assembly into a comfortable working position as
shown in (Figure 8).

Step Two:

Remove bolt and blade cap using a SAE

9/16” wrench (Figures 9 & 10) Carefully

remove old blade. Inspect arbor shaft,

backing plate and blade guard while

blade is off. Clean if dirty or replace if

damaged or worn.

Step Three:
Look for “direction of rotation” markings on the blade.
(Usually an arrow stamped on the blade.) Place new blade on
the arbor shaft verifying that once installed the markings on the
blade follow the proper direction of rotation. (Figures 11 & 12)

Reinstall blade cap and tighten bolt using a SAE 9/16” wrench.

Repeat step #1, reposition blade guard assembly and tighten.
Reconnect power plug.

Maintenance

Disconnect power plug lead before performing

any maintenance on this machine.

Consult the Motor Manufacturer’s Owner’s Manual for more detailed motor maintenance instructions.