EVCO EVCLC33DJ2 User Manual
Page 45
Advertising

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 45 of 66
16.2
Setting
the
configuration
parameters
Operate as follows to access the procedure:
1.
Ensure that the device is switched on and that no
other procedure is in progress.
2.
Touch
.
3.
Touch “SERVICE”.
4.
Touch
or
to set the password
“-19”.
5.
Touch
to confirm.
Operate as follows to select a parameter:
6.
Touch
or
to select the relevant parameter.
Operate as follows to set a parameter:
7.
Touch the relevant parameter
8.
Touch
or
to set the value.
9.
Touch
to confirm.
Access to the configuration parameters setting procedure.