EVCO EVC30S40J7XXX09 User Manual
Page 12

12/13
output can be activated at the start of the cycle following deactivation
of the input.
4.11. Some regulation times
4.11.1. Example 1
Initial conditions
P5=0
Preservation not selected from key
Operation
P.I.D. regulation on P2 (dedicated parameters P11…P15)
LED
L1 on if probe 1 in [P2-P6,P2+P6]
L1 flashing if probe 1 is outside [P2-P6,P2+P6] range for time P7
L2
off
What can I do?
Press the [MELT] key for 1 second and pass to pre-heat mode if probe 1 <P8
Press the [MELT] key for 1 second and pass to preservation mode if probe 1
≥P8
4.11.2. Example 2
Initial conditions
P5=1
Preservation not selected from key
Operation
Pre-heat mode until probe 1 reaches P8 for the first time
P.I.D. regulation on P2 (dedicated parameters P11…P15) once pre-heating has
ended
LED
L1 flashing during pre-heat
L1 on if pre-heat ended and probe 1 in [P2-P6,P2+P6]
L1 flashing pre-heat terminated and if probe 1 is outside [P2-P6,P2+P6] range for
time P7
L2
off
What can I do?
Press the [MELT] key for 1 second to pass to preservation mode
4.11.3. Example 3
Initial conditions
Preservation selected by pressing the key [MELT] before Start.
Operation
Pre-heat mode until probe 1 reaches P8 for the first time
Preservation i.e. P.I.D. regulation on P8 (dedicated parameters P11…P15) once
pre-heating has ended
LED