User interface, Setting the set-point, Setting the timer – EVCO EVC30S40J7XXX09 User Manual
Page 2
2/13
1. USER
INTERFACE
FUNCTION KEY FUNCTION
B1 START
B2 MELT
B3 DISPLAY
B4 TIMER
B5 TIMER
1.1. Setting the set-point
To access the procedure
• Press the [ENCODER] button, LED L3 flashes.
To modify the value
• Turn the encoder within 15 seconds
To exit the procedure
• Press the [ENCODER] button or do not operate on the keyboard for 15 seconds
1.2. Setting the timer
The value of the timer can be set within 0 and 99 minutes.
To access the procedure
• Make sure the timer is in the stop status.
• Press the [B4] key, the min LED flashes, the value on the display flashes.
Alternatively
• Press the [B5] key, the min LED flashes, the value on the display flashes.
To modify the value
• Turn the encoder within 15 seconds
To exit the procedure
LED FUNCTION
L1 START
LED
L2 MELT
LED
L3 DISPLAY
LED
L5 ALARM LED
°C Celsius
LED
°F Fahrenheit
LED
min TIMER
LED