2 the c-pro micro wiring layout – EVCO c-pro micro User Manual
Page 9
Advertising

C-PRO MICRO HARDWARE MANUAL
Page 9
3.2
The C-PRO MICRO wiring layout
The C-PRO MICRO control unit wiring layout is shown below, with the meanings of the inputs and outputs
given in the tables.
C-PRO MICRO wiring diagram
Connector 1:
Output relay connection
Conn.
Abbrev.
Description
C1-1
DO1
Relay No.1, breaker normally open
C1-2
COMMON DO1
Relay No. 1 - common
C1-3
DO2
Relay No.2, breaker normally open
C1-4
COMMON DO2
Relay No. 2 – common
C1-5
DO3
Relay No.3, breaker normally open
C1-6
COMMON DO3
Relay No. 3 - common
C1-7
DO4
Relay No.4, breaker normally open
C1-8
COMMON DO4, DO5
Relay No.s 4,5 - common
C1-9
DO5
Relay No.5, breaker normally open
C1-11 DO6
Relay No.6, breaker normally open
C1-12 COMMON DO6
Relay No. 6 - common
Advertising