WORKING SETPOINT SETTING
The working setpoint is programmable within the lim-
its established with the parameters r1 and r2.
To modify the working setpoint value:

a) keep pushed the key

•

the instrument displays the actual value

•

the compressor LED flashes quickly

b) push and release the key

or

as long

as the instrument displays the desired value

•

the working setpoint value gets increased or decreased

c) after the modify release the key

last

•

the instrument automatically turns out from the working

setpoint setting procedure.

CONFIGURATION PARAMETERS SETTING
Configuration parameters are arranged on two levels.
To gain access to the first level:

a) keep pushed for four seconds at least the keys

and

•

passed four seconds the instrument displays the label

PA

To select a parameter:

a) push and release the key

or

as long

as the instrument displays the label of the de-
sired parameter

To modify a parameter value:

a) keep pushed the key

•

the instrument displays the actual value

b) push and release the key

or

as long

as the instrument displays the desired value

•

the parameter value gets increased or decreased

c) after the modify release the key

last

•

the instrument displays the label of the parameter again

To gain access to the second level:

a) enter inside the first level and select the label

PA

b) keep pushed the key

•

the instrument displays the actual value

c) push and release the key

or

as long

as the instrument displays -19

•

the label value gets increased or decreased

d) after the modify release the key

last

•

the instrument displays the label PA again

e) keep pushed for four seconds at least the keys

and

•

passed four seconds the instrument displays the first pa-

rameter of the second level

To turn out from the configuration parameters
setting procedure:

a) keep pushed for four seconds at least the keys

and

or do not operate with the keys

for fifty seconds at least.

ENGLISH

EC 6-294

EC 6-294

EC 6-294

EC 6-294

EC 6-294

Quick reference

1

4

communication

n0

0

2

---

0

instrument functioning in the network (®)

n1

0

8

---

0

instrument address (®)

n3

0

1

---

0

enabling to work as slave instrument (§) (®)

n4

0

240

sec.

0

delay to the resources implementation in the slave instrument (®)

nA

0

15

---

0

resources to implement in the slave instrument (®)

Additional informations:

• the symbol (§) indicates that the parameter is of the first level
• the symbol (*) indicates that the unit of measure depends from the parameter /8
• the symbol (®) indicates that the parameter is available on request only
• the symbol (**) indicates that the unit of measure depends from the parameter db.