EVCO EC6294 User Manual
Page 6

WORKING SETPOINT
Label Min. Max. U.m. Stand.
Working setpoint
r1
r2
(*)
0
working setpoint
CONFIGURATION PARAMETERS
Label Min. Max. U.m. Stand.
Password
PA
-55
99
---
0
password (§)
Label Min. Max. U.m. Stand.
Measure inputs
/0
1
4
---
1
kind of probe
/1
-55
+99
(*)/8
0
calibration (§)
/2
0
6
---
3
digital filter
/8
0
1
---
1
unit of measure
/A
0
1
---
1
evaporator probe enabling
Label Min. Max. U.m. Stand.
ON-OFF temperature regulator associated to the work-
ing setpoint and to the compressor output
r0
+1
+15
(*)
+2
hysteresis (differential) (§)
r1
-55
+99
(*)
-50
minimum working setpoint programmable
r2
-55
+99
(*)
+50
maximum working setpoint programmable
Label Min. Max. U.m. Stand.
Compressor output protection
C0
0
240
(**)
1
disabling time to the output activation from the instrument start
C1
0
240
(**)
5
disabling time to the output activation from the previous activation
C2
0
240
(**)
3
disabling time to the output activation from the previous deactiva-
tion
C4
0
1
---
0
disabling time to the output activation and deactivation
C5
1
240
(**)
10
cycle time for the output activation during a cabinet probe failure
alarm
C6
0
100
%
50
percentage of the cycle time during which the output gets acti-
vated during a cabinet probe failure alarm
Label Min. Max. U.m. Stand.
Defrost regulator
d0
0
99
(**)
8
defrost interval
d1
0
1
---
1
kind of defrost
d2
-55
+99
(*)
+2
defrost stopping setpoint
d3
1
99
(**)
15
defrost maximum length
d4
0
1
---
0
defrost cycle at the instrument start
d5
0
99
(**)
0
delay to a defrost cycle activation from the instrument start
d6
0
1
---
1
locking of the displayed temperature from a defrost cycle activation
d7
0
15
(**)
2
dripping length
d9
0
1
---
0
disabling times to the compressor output activation override
dA
---
---
(*)
---
evaporator probe reading (§)
db
0
1
---
0
times base
Label Min. Max. U.m. Stand.
Alarm regulator
A0
+1
+15
(*)
+2
hysteresis (differential)
A1
-55
0
(*)
0
lower temperature alarm set relative to the working setpoint
A2
0
+99
(*)
0
upper temperature alarm set relative to the working setpoint
A3
0
240
(**)
120
disabling time to the temperature alarm activation from the instru-
ment start
A5
-1
120
(**)
30
disabling time to the buzzer activation for the multifunction digital
input alarm indication
A6
0
240
(**)
5
disabling time to the temperature alarm activation
A7
0
240
(**)
15
disabling time to the temperature alarm activation from the defrost
cycle end
Label Min. Max. U.m. Stand.
Evaporator fans regulator associated to the evaporator
fans output
F1
-55
+99
(*)
-1
output deactivation setpoint
F2
+1
+15
(*)
+2
hysteresis (differential)
F4
0
2
---
0
output functioning during the defrost and the dripping
F5
0
15
(**)
2
evaporator fans stoppage length
F6
0
1
---
0
kind of output deactivation setpoint
F7
0
4
---
4
output functioning during the normal functioning
Label Min. Max. U.m. Stand.
Digital inputs
i0
0
5
---
4
action given during the multifunction digital input activation
i1
0
1
---
0
kind of contact of the multifunction digital input
i2
0
2
---
0
action given during the locking digital input activation (®)
i3
0
15
---
0
number of locking digital inputs alarm enough to give the instru-
ment locking (®)
i4
0
240
(**)
0
time required to clear the locking digital inputs alarm counter (®)
i5
0
15
(**)
0
disabling time to the compressor output activation from the previ-
ous locking digital input deactivation (®)
Label Min. Max. U.m. Stand.
User-output configuration
u1
0
6
---
0
user to associate to the output K 1A (®)
u2
0
6
---
1
user to associate to the output K 2A (®)
u3
0
6
---
2
user to associate to the output K 4A (®)
u4
0
6
---
3
user to associate to the output K 3A (®)
u5
0
6
---
5
user to associate to the output K 5A
Label Min. Max. U.m. Stand.
Connection in a serial network with EVCOBUS protocol
communication
L1
1
15
---
1
instrument address
L2
0
7
---
0
instrument group
L3
7
240
sec.
30
time-out link
L4
0
3
---
1
baud rate
Label Min. Max. U.m. Stand.
Connection in a serial network with EVCONET protocol
2
3