EVCO EC6295S001 User Manual

Page 4

Advertising
background image

evapora-

tor probe

alarm

multi-

function

input

alarm

upper

tempera-

ture alarm

• the connection in-

strument-cabinet

probe is wrong

• the cabinet tempera-

ture is outside the

limits allowed by the

working range of

the instrument

• the kind of evapora-

tor probe you have

connected is not

right

• the evaporator

probe plays up

• the connection in-

strument-evaporator

probe is wrong

• the evaporator tem-

perature is outside

the limits allowed by

the working range

of the instrument

the multifunction input

is active.

Unless the parameter

i6 has value 1, the in-

strument will not show

any indication

the cabinet tempera-

ture is outside the limit

you have set with the

parameter A1b

• test the temperature

close to the probe (it

has to be between

the limits allowed by

the working range)

• look at the param-

eter /0

• test the integrity of

the probe

• test the instrument-

probe connection

• test the temperature

close to the probe (it

has to be between

the limits allowed by

the working range)

deactivate the input

(look at the parameters

i0, i1 and i6)

test the temperature

close to the probe

(look at the parameters

A0, A1b and A2b)

• if the defrost is run-

ning, it will immedi-

ately end

• the defrost will

never be activated

• if the parameter dE

has value 2, the in-

strument will work

as if the parameter

had value 0

• if the parameter F7

has value 3 or 4, the

evaporator fan will

work in accordance

with the compres-

sor, except what

you have set with

the parameters F4

and F5

• the defrost will end

by time (parameter

d3)

you will get the action

you have chosen with

the parameter i0

no effects

for 3 s

every 4

lower

tempera-

ture alarm

for 3 s

every 4

real time

clock

alarm

slave

alarm

there has been an up-

per temperature alarm

the cabinet tempera-

ture is outside the limit

you have set with the

parameter A1A

there has been a lower

temperature alarm

there is the corruption

of the data of the clock

of the instrument

the instrument will be

set as slave, among

the remote controls,

coming from the mas-

ter, the slave has to

implement there will

be the comp. status

and there will be one

of the alarms you saw

in the previous cases.

If the master is in the

STAND-BY mode and

the slave is ON, the in-

dication will be

showed every 2 s alter-

nated with the alarm

code

look at the parameters

A0, A1b, A2b, A8 and

A9

test the temperature

close to the probe

(look at the parameters

A0, A1A and A2A)

look at the parameters

A0, A1A, A2A, A8 and

A9

set the clock again

• if you have to show

the alarm code,

press

• look at the remedies

of that case

no effects

no effects

no effects

• if the parameter dE

has value 3, the in-

strument will work

as if the parameter

had value 0

• the Energy Saving

cycle will never be

activated

look at the effects of

that case

LABEL MIN. MAX. U.M.

DEF. DIGITAL INPUTS

i0

0

7

---

4

action given by the multifunction input activation (0 = inactive, 1 = once d5 has passed, the

defrost will be activated

(7)

, 2 = the cabinet light will be turned ON, 3 = the compressor will be

forced ON for A5 and the cabinet light will be turned ON, 4 = the compressor and the

evaporator fan will be forced OFF for A5 and the cabinet light will be turned ON,

5 = the evaporator fan will be forced OFF for A5 and the cabinet light will be turned ON,

6 = the working setpoint becomes r8, 7 = the working setpoint becomes r8 and the cabinet

light will be turned OFF); look at i7 as well

i1

0

1

---

0

kind of contact of the multifunction input (it is important if i0 ≠ 0; 0 = NO, 1 = NC)

i2

1

2

---

1

action given by the lock input/thermal protection activation (1 = the compressor will be forced

OFF, 2 = in accordance with i3, i4 and i5)

i3

0

15

---

0

lock input/thermal protection alarms number such as to give the lock of the instrument (it is

important if i2 = 2; 0 = the lock of the instrument will never take place)

i4

i5

240

min

0

time without lock input/thermal protection alarms able to clear the lock input/thermal pro-

tection alarms counter (it is important if i2 = 2)

i5

0

15

(14)

min

0

minimum delay between the lock input/thermal protection deactivation and the following

compressor activation (it is important if i2 = 2)

i6

0

1

---

1

indication “Ain” flashing on the display during the multifunction input activation (it is impor-

tant if i0 ≠ 0)

i7

0

240

min

0

delay between the multifunction input deactivation and the cabinet light gets OFF (it is

important if i0 = 2, 3, 4 or 5)

(15)

LABEL MIN. MAX. U.M.

DEF. SERIAL NETWORK (EVCOBUS)

L1

1

15

---

1

instrument address

L2

0

7

---

0

instrument group

L4

0

3

---

1

baud rate (0 = 1,200 baud, 1 = 2,400 baud, 2 = 4,800 baud, 3 = 9,600 baud)

LABEL MIN. MAX. U.M.

DEF. SERIAL NETWORK (EVCONET)

n0

0

2

---

0

operation of the instrument in the network (0 = instrument not enabled to work in the

network, 1 = master, 2 = slave)

(16)

n1

0

8

---

0

address of the instrument in the network (it is important if n0 ≠ 0; 0 = master address,

1 ... 8 = first ... eighth slave address)

n3

0

1

---

0

authorization to implement the remote controls coming from the master (it is important if

n0 = 2 and n1 ≠ 0; 1 = YES)

n4

0

240

s

0

time between the master implements a control and the slave implements the same control (it

is important if n0 = 2 and n1 ≠ 0); look at nA as well

(17)

(18)