Inputs, Offset, Smux proof – Expert Sleepers Silent Way v2.4.3 User Manual

Page 52

Advertising
background image

Inputs

The “Inputs” section sets up the routing from the plug-in inputs to the hardware outputs.
Each control may be set to “Off” which disables that input.

The “Thru” input chooses a stereo pair of inputs which will receive a signal from another
Silent Way plug-in which is outputting a signal for the ES-4/5 e.g. from the ES-4 Control-
ler, from Silent Way Sync (in ES-4 mode) or from the Voice Controller (in ES-4 mode). Use
this input to stack plug-ins on a single track to address multiple ES-4/5/expanders at the
same time.

The drop-downs labelled “1” to “8” choose a plug-in input that will be routed to the corre-
sponding output of the ESX-8CV.

Offset

The “Offsets” controls let you dial in a voltage offset on each ESX-8CV output. The values
on the controls are in Volts (assuming the ESX-8CV’s jumper is not fitted, and the calibra-
tion trimmer is at the factory default setting).

SMUX Proof

The ‘SMUX Proof’ button modifies the output of the plug-in to be
compatible with the

Silent Way SMUX

plug-in. It should be acti-

vated whenever the SW ESX-8CV Combiner’s output is being
passed through the SW SMUX plug-in, typically when running at double sample rates
(88.2/96kHz) with an Expert Sleepers ES-3 module.

Advertising