3.
Introduction and Specifications
The all-in-one Digital Amplifier DAD 141.1 is a universal device for any weighing, filling or loss-in-weight
operation and for force measurements with strain gage sensors. The DAD141 is for DIN (TS35) rail mount.
To grant the quality and allow legal weighing the DAD141.1 is OIML R-76 approved (pending) and meet the
MID E2 requirements to EMC.
The standard device includes all the communication facilities needed for industrial weighing, control and
registration, i.e. analog current or voltage output (0/
4…20 mA, 0…5V, 0…10V, -5V…+5V and -10V…+10V),
Ethernet, RS 422/
485 and logic I/O’s for direct control of valves or bars etc.
The device can be controlled either by the front keys, via RS 422/485 port or Ethernet port. 2 logic inputs and 3
logic outputs make complex control functions easy. The 3 logic outputs can be controlled external, too.
The device features fullfills multi-drop communications capability and can be programmed via a straightforward
ASCII command set. You can connect up to 32 DAD 141.1onto a single RS485 bus.
DAD 141.1 Specifications
Accuracy class
III
Test certificate according OIML R76
EU Type approved for 10000 intervals
AD converter
Delt-Sigma, ± 24 bit
Analog input range
±15 mV bipolar (± 3 mV/V @ 5 VDC excitation)
Minimum input sensitivity
0.25
μV/e (legal for trade); 0.05 μV/d (non legal for trade)
Linearity
< 0.001 % FS
Temperature effect on zero
< ±4 ppm/°K (typical < ±2 ppm/°K)
Temperature effect on span
< ±8 ppm/°K (typical < ±4 ppm/°K)
Excitation
5 V DC, load cell(s) resistance 50 - 2000 ohms; 6 wire technic
Conversion rate
Max. 600 values/second, selectable in 8 steps
Resolution external
± 600 000 counts @ ± 3 mV/V input signal
CALIBRATION & WEIGHING FUNCTIONS
Calibration
Electronical calibration in mV/V (eCal) or with test weight(s)
Digital low pass filter
FIR Filter 2.5 to 19.7 Hz or IIR Filter 0.25 to 18 Hz - adjustable in 8 steps
Weighing functions
Zero, gros, tare, net, filter, etc.
Application modes
None automatic weighing instrument (NAWI) or triggered measurement
Communication & Setup
Communication ports
RS 422/485 and Ethernet
Setup & Calibration
Panel buttons or Windows software ‘DOP 4’ or smartphone App ‘AnDOP’
Display
6 digit 7 segments, green LED’s, 5.08mm, 8 status LED green,
spectral filter 565 nm for improved contrast
Keyboard
4 pcs, Ø 3mm robust, for setup / calibration, zero, tare
Power supply
12 ... 24 V DC ±10 %, < 4 W
Environmental Conditions
Operating temperature
-15 °C to +55 °C at maximal 85% rh, non condensing
Storage temperature
-30 °C to +70 °C
Enclosure & protection
Plastic housing, for DIN rail mount (TS35) , protection IP40
Dimensions and weight
120 x 105 x 22.5 mm (H x L x W), weight approx. 170 g
EMC performance
EN61326 according to MID E2 for industrial applications (in full
accordance with 2004/22/EC)
Vibration resistance
2.5g @ operation, 5g @ storage
Serial Interface
RS 422/485, 9600 ... 115200 Baud
– half/full duplex
Protocol & Address range
ASCII; address range
1 … 31
Modbus RTU
Binary data
Ethernet interface
RJ45, 10/100 Mbit/s, isolated
Ethernet TCP/IP
– protocol & port
protocol ASCII, TCP port 23
Modbus TCP
– protocol & port
Embedded in TCP/IP packages, protocol binary data, TCP port 502
IP address
Setup via serial port or panel buttons – Factory default: 192.168.0.100
Analog current output
0
– 20mA or 4 – 20mA, 500ohm, isolated or
Analog voltage output
0
– 10V, 0 – 5V, ±5V, ±10V, 10kohm, isolated
Digital logic inputs
2 inputs (10
– 30V, 1 – 3mA), commond ground, isolated
Digital logic outputs
3 outputs (semiconductor relais) 30 V DC/AC, 0.5 A,
common ground, isolated