Index (hex)

Type

Size Access Function

2000

Float

2

R

Gross Weight

This Index returns the latest Gross value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2000.
The Gross Weight are also sent when reading multiple DAD141 data at index 3500.
see also command description:

GG get gros value

2002

Float

2

R

Net Weight

This Index returns the latest Netto value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2002.
The Netto Weight are also sent when reading multiple DAD141 data at index 3500.
see also command description:

GN get net value

2008

Float

2

R

Average Weight

This Index returns the latest average weight value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2008.
see also command description:

GA get average value

2020

Int32

2

R

Gross Weight

This Index returns the Gross weight value obtained from a DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 2020.
The Gross Weight are also sent when reading multiple DAD141 data at index 3300.
see also command description:

GG get gros value

2022

Int32

2

R

Net Weight

This Index returns the Netto weight value obtained from a DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 2022.
The Netto Weight are also sent when reading multiple DAD141 data at index 3300.
see also command description:

GN get net value

2028

Int32

2

R

Average Weight

This Index returns the latest average weight value obtained from a DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 2028.
see also command description:

GA get average value

202A

Int32

2

R

A/D Sample

This Index returns the current ADC value obtained from a DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 202A.
see also command description:

GS get sample

202C

Int32

2

R

Device ID

This Index returns the current ID of a DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 202C.
The the high word (202C) are 0(zero) and the low word (202D) should be split into two bytes:
1. Byte is the minor ID, normally 10h (16d).
2. Byte is the major ID, normally 14h (20d).
see also command description: