Junction Box Type KPB-4 – Technical Manual, Rev. 1.00 September 2007

Page 3 of 4

I

NTRODUCTION AND TECHNICAL

D

ATA

The plastic junction box is designed for the parallel connection of 4 load cells type PB or type PBW.
There are 2 versions available.

Type

No. of load cells

Housing size

Inputs Output

Vers.

Potentiom. Accuracy cl.

1

10 Ω

C3

KPB-4

up to 4x type PB/PBW 100 x 100 x 40 mm

4

1

2

50 Ω

GP

The junction box type KPB-4 can be connected to the instrumentation with a shielded 6-wire signal cable.
The corner correction is done with potentiometer.

Housing material:

Plastic

Protection class:

IP54

Cable connection:

Load cell cable with plug connector AMP #103957-4; output cable by soldering

Corner correction:

By potentiometer

M

ECHANICAL

I

NSTALLATION

Look for a mounting location which is more or less dry and protected from environmental stress.
Before you mount the junction box you should prepare (drill) a holl for the output cable.

E

LECTRICAL

C

ONNECTIONS

Figure 1: Dimensions in [mm]

The connection sequence of the load cells should correspond to the corners of the scale, i.e
Corner 1 = Load cell 1, Corner 2 = Load cell 2, etc.

L

OAD

C

ELL

C

ABLE

C

ONNECTION

Connect the load cell cable with its plug connector to the prepared plug connector on the printed circuit board.
Afterwards prepare the load cell cable with the delivered cable sleeve, so that later on the cable inlet gets tight
and the plug connector stress relieved.

The load cell cable connections at the AMP- plug are as follows:

Cable coulour

Description

Pin no.

Plug connector load cell cable (top view)

red

= Signal – (Output –)

5

white

= Signal + (Output +)

4

black

= Excitation – (Input –)

2

green

= Excitation + (Input +)

1

1 2 4 5

1 2 4 5

1 2 4 5

1 2 4 5





Advertising