Flintec, Lac 74.1, The right weigh – Flintec LAC 74.1 User Manual

Page 2: System configuration, Lac 74.1 specifications, Page 2 manual lac 74.1

Advertising
background image

...the right weigh

FLINTEC

Page 2

Manual LAC 74.1

Open Collector output,

normally closed,

opens in case of

LAC 74.1 error

IN mV

% at
2mV/V

SET ZERO Pot ccw = calib.

Fine

adj.

0

0,5

1,0

2,0

4,0

8,0

16,0

0

2,5

5

10

20

40

80

Pol.

+/-

Relative

gain

*

Resolu.

*

1000 n

SET SPAN Pot ccw = calib.

0,25

0,5

1,0

2,0

4,0

8,0

16,0

40

30

20

13

7

4

50

60

1,0

Fine

adj.

f

CUT

t

ms

SET

FILTER

5

33

16

10

50

3,3

160

1

500

0,33

OUTPUT

CND

Error

Pwr

.

OK

20mA/10V

0-20/4-20

Under

In

range.

Over

LOAD CELLS 10Vdc 120mA

Log Err.

PWR

12-24Vdc

GND

+

U

Gnd

C

Exc Sen Inp Inp Sen Exc

+ + +

_ _ _

Gnd I/V

LAC 74.1

Off

On

Out

20mA/

10V

PLC and/or

computer with

analogue input

FLINTEC

Load cells

6-wire

connection

;

PLC

system

Silo Nr.:

1

Netto

: 17285 kg

Tara

: 1458 kg

Power supply

-----------------------

12...24 V DC

14...28 V AC

System Configuration

Linearity

< 0.01 %

Analogue input range

±0.1 mV/V to 3.5 mV/V, gain adjustment by DIP-switches and fine trimming
potentiometer

Excitation

10 V DC, for up to 4 load cells 350 Ohm, 6 wire technique

Safety circuit

Logic output, Open Collector, normally closed, opens in case of error (max. 30 V
DC, 300 mA):

- Load cell input- or sense wires signals are out of range
- The current or voltage output is out of range
- Power fail

Zero adjustment (Offset)

±3 mV/V, zero adjustment by DIP switches and fine trimming potentiometer

Current output

0 ... 20 mA or 4 ... 20 mA; R

Load

³

500 Ohm

Voltage output

0 ... 10 V; R

Load

³

500 Ohm

Input filters

0.33 ... 33 Hz, DIP switch selectable (5 steps)

Temperature range

–20 °C to +50 °C (operating); –20 °C to +60 °C (storage)

Temperature effects

on zero

25 ppm/°K

on span

50 ppm/°K

Enclosure

135 x 66 x 18 mm, protection IP40, for standard 35 mm DIN-rail mounting,
(special housing on request)

Power supply

12 ... 24 V DC ±10% or 12 ... 18 V AC, 3 W max., reversed polarity and excess
voltage protected

All dimensions in mm. Dimensions and specifications are subject to change without notice.

LAC 74.1 Specifications

Advertising