background image

Calibration of the analogue output

1. Mounting the module

The SG module has to be installed in a cabinet in compliance with (inter)national electrical
regulations. Connection details are printed on the upper face of the amplifier housing.
The amplifier module supports 6 wire technique. If you are using a 4 wire load cell, the
“Exc +” and “Sen +” terminals must be shorted together as well as the “Exc –“ and “Sen –“
terminals.

2. Adjustment settings

All DIP-switches and potentiometers are positioned near the top edge of the housing.

3. Setup DIP-switches

Zero setting:

The left six DIP-switches permit the off-set to be adjusted in steps of 0.5 mV throughout the
range of 0 to 31.5 mV. The seventh DIP-switch sets the polarity of the zero adjustment, either
Positive (ON) to make the output more positive or Negative (OFF) to make the output more
negative. The 20-turn potentiometer permits fine trimming of the zero point.
The total range is + or – 80%.

DIP-switch ON

none

1

2

3

4

5

6

all

Pol.

Pot.

Relative to 20 mV

%

0

2.5

5

10

20

40

80

157.5

+/–

3

Input at Zero V

out

mV

0

0.5

1

2

4

8

16

31.5

+/–

0.6

Span (Gain) setting:

The seven DIP-switches permit the relative gain to be set in 128 steps of 0.25x over the range
1 to 32. The 20-turn potentiometer permits fine trimming. Therefore, any input signal range
between 0.1 mV/V and 3.2 mV/V can be used to generate the full scale output (0 – 10 V or
0 – 20 mA or 4 – 20 mA). Note that the higher the gain, the lower the resolution that can be
obtained.

DIP-switch ON

none

1

2

3

4

5

6

7

all

Pot.

Relative gain factor

f

1

0.25

0.5

1

2

4

8

16

33

0.3

Input at 10V V

out

mV

32

30

28

24

16

8

4

2

1

xx

FLINTEC

...the right weigh

Manual LAC 74.1

Page 3

DIP-switches for choosing
analogue output
0-20 mA or 4-20 mA or 0-10 V.

33

10

3,3

1

0,33

OUTPUT

Error

Power

O

K

20mA

o.10V

0-20

o.

4-20mA

CND

5

16

50

160

500

SET

FILTER

f

CUT

ms

0,1

0,25

0,5

1,0

2,0

4,0

8,0

16,0

SET SPAN Pot ccw =calib.

Relative
gain*

Resolution
*1000n

Fine

adjust

60

50

40

30

20

13

7

4

0

0,5

1,0

2,0

4,0

8,0

16,0

SET ZERO Pot ccw =calib.

IN

% at
2mV/V

Fine

adjust

0

2,5

5

10

20

40

80

Pol.

+/-

mV

DIP-switches and

potentiometer

for zero setting

DIP-switches and

potentiometer

for gain setting

DIP-switches

for low pass filter

0.5-33 Hz

Under

In

range

Over

OFF

ON

Under

In range

Over

Error

Power OK

=
=
=
=
=

signal out of range (e.g. negative too)

input signal OK

signal out of range (e.g. > 2 mV/V)

error message safety logic

power is ON