Using Limit Level Indicator

The final setting of the bypass for best performance has always
been something of a black art. The 3-Zone System has a new
feature to simplify this adjustment. While the system is operating,
these limit level numbers, if greater than zero, are flashed on the
status LED.

Once the proper LAT limit choice is made based on equipment
maximum rise, the limit level indicator assists in setting the bypass
pressure adjustment. See System Setup for details.

Installer Test Mode

Dipswitch 4 selects a special Installer Test Mode, designed to
assist the installer (or service person) to commission the system. It
verifies damper movement in proper zone and that the heating and
cooling equipment operates properly at each stage. When this
mode is selected, by moving dipswitch 4 to ON, the following
sequence will be executed once:

Step 1 — Two minutes, one flash of status LED. The blower is
energized with G, damper 1 opens, and other dampers are closed.

Step 2 — Two minutes, two flashes of LED: With the blower on,
damper 1 closes and damper 2 opens.

Step 3 — Two minutes, three flashes of LED: With the blower
ON, damper 3 opens and damper 2 closes.

Step 4 — Two minutes, four flashes of LED: All dampers open,
first stage of heat turns on. For HP control only, this is followed by
the second stage of heat (HP plus aux heat, hi HP, or hi furnace)
for two more minutes. For HP control with two stage compressor,
the third stage of heat (hi HP plus aux heat) comes on for a third
2 minute period.

Step 5 — Two minutes, five flashes of LED: All dampers are open
and first stage of cooling turns on for 2 minutes. For HP board
only, second stage of cooling comes on for an additional 2
minutes.

At the end of Step 5, the control returns to normal operation. To
restart the test sequence, the switch must be moved to OFF and
then back to ON.

If zoning is disabled (Switch 5 = ON), the procedure above will be
followed, except all the dampers will remain open throughout the
sequence.

SYSTEM SETUP

Thermostats

Read the thermostat Installation Instructions and be sure to
complete the required setup of these devices before using them to
bring on the equipment. If the thermostats have a

″zoning″

selection, be sure to turn it on. This will eliminate the timers within
the thermostat and allow the 3-Zone control’s timers to do their
job.

There are 8 dipswitch settings on the AC zone control and an
additional 4 on the HP board. Below is a table summarizing their
function. Below the table is a more detailed description of what
each does and how to set it properly for your application.

Dipswitches

Dipswitch 1- This determines whether or not a minimum time
must pass before the control is allowed to transition between
heating and cooling or vice versa. If it is set to ON, there is no time
requirement. Default is OFF.
Dipswitch 2 - This switch, together with dipswitch 3, determines
the changeover time, effective if switch 1 is OFF. ON sets 30
minutes. OFF sets 20 minutes. Default is OFF.
Dipswitch 3 - This is a multiplier, modifying the time set on switch
2. ON multiplies the set time by 0.5. OFF multiplies the set time
by 1.0. Default is OFF.
Dipswitch 4 - This selects the Installer Test Mode, used to check
system operation. Details are provided in section Installer Test.
ON selects Installer Test. OFF selects normal operation. Default is
OFF.
Dipswitch 5 - Enables and disables zoning. ON disables zoning,
with all dampers open and zone 1 thermostat controlling. OFF
selects normal zoning operation. Default is OFF.
Dipswitch 6 - Selects G ON or OFF with W. Selecting ON causes
G to be energized whenever W is energized. Selecting OFF does

Table 2—Limit Temperature Levels and Actions

LIMIT LEVEL

0

1

2

3

4

5

6

7

Cooling Limit (40 deg) above

47

46

45

44

43

42

41

40

HP limit (115 deg) below

107

108

109

110

111

112

113

115

Heat Limit (130 deg) below

119

121

122

124

125

127

128

130

Heat Limit (145 deg) below

131

133

135

137

139

141

143

145

Heat Limit (160 deg) below

143

145

148

150

153

155

158

160

Heat Limit (175 deg) below

155

158

161

164

166

169

172

175

LIMIT ACTIONS

Closed

Damper Positions

0

2

4

6

8

10

12

14

Allowed stages (1 stg)

1

1

1

1

1

1

1

0

Allowed Stages (2 stg)

2

2

2

1

1

1

1

0

Allowed stages (3 stg)

3

3

3

2

2

1

1

0

Table 3—Dipswitch Settings

DIPSWITCH 1 POSITION

ACTION

(OFF)

ACTION

(ON)

1

Auto changeover Timer

Active

Defeat

Auto Changeover

Timer

2

Auto Changeover 20 Min-

utes

Auto Changeover

30 Minutes

3

Auto Changeover Timer X

1

Auto Changeover

Timer X .5

4

Normal Operation

Installer Test

5

Zoning Enabled

Zoning Disabled

6

Fan With W Disabled

Fan With W Enabled

7

LAT Setting

LAT Setting

8

LAT Setting

LAT Setting

Table 4—Dipswitch Settings

for HP Control Only

DIPSWITCH 2 POSITION

ACTION

(OFF)

ACTION

(ON)

9

HP Operation

AC Operation

10

HP Thermostat

AC Thermostat

11

LAT and HPT

Safeties Enabled

LAT and HPT

Safeties Disabled

12

Reversing Valve Ener-

gized in Cooling (O)

Reversing Valve

Energized in Heating (B)

7

Advertising