Fredenstein Bento 10D Module Carrier

To recall stored select Memory and push the wheel and the number of the setup is highlighted, turn
the wheel to the number you want to use, then press the wheel to recall this configuration. Selecting
Exit and pushing the wheel will show the Setup Menu again.

In case of severe ground loops you might engage the ground-lift to alleviate such problems. But it is
always recommended to resolve the grounding problems at their source and keep the ground-lift
switch disengaged (OFF). Select Lift and push the wheel to toggle between off and on. Selecting
Exit and pushing the wheel will show the Setup Menu again.

The display brightness can be chosen by selecting Intensity and then pressing the wheel, turning the
wheel left or right, you can set the desired brightness. Pushing the wheel sets this value and bring
you back to function select. Selecting AutoDim ON will reduce the brightness of the display after
90 seconds of inactivity. It is recommended to use AutoDim to extend the life cycle of the LCD
back-light. Selecting Exit and pushing the wheel will show the Setup Menu again.

Error Messages:

If one of the power fails due to either a defect or an overload condition caused by a faulty module
inserted in the Bento 10D, the status will be updated to failure and the voltages displayed will help
to identify the problem. Remove one module at the time and find out, which one caused the
problem.
Bento 10D supports Fredenstein digital link between the modules and the display. In case there is a
malfunction on this interconnect, the display will show “Bus Trouble”. Please also remove the
modules one by one to see which one caused the problem.

Fredenstein Bento 10D Manual V2.0 September 24, 2014 Page 4

Advertising