Operation Normal/High Speed Mode Select

The operation mode is set on "Normal mode" from the factory. To

change the mode please follow the steps below.

1

Turn off the receiver.

2

Press and hold the

Link/Mode button and turn on the receiver.

Press and hold the button for more then 1 second. The LED

will start to flash and will indicate the current status.

3

Release the button.

4

Turn off the receiver.

By following these steps the receiver modes can be switched back and

forth between normal and high speed modes.

0 to 1 sec.

More than 1 sec.

0 sec.

1 sec.

Press and Hold

Turn on the receiver.

No function

Showing the CURRENT
mode with blink.

Red Blink = Normal

Green/Red Blink =
High Speed

Solid as the mode changed.

Red Solid = Normal

Green/Red Solid = High
Speed

(Become

Red after 1 second)

Function)

To change the mode between
Normal and High Speed

LED Status)

Please check the operation mode by observing the LED when turning on

the receiver. The best way to confirm the mode you are on is to make sure

that there are no other

FASST transmitters turned on around you.

When turning on the receiver, the LED will be;

• Red when on "Normal mode"

• Green and Red (making orange) when on "High Speed mode". (After 2

seconds, the LED will change to red.)

If there are any FASST transmitters turned on around the receiver, the

LED may show the above status, but just for a brief moment and then

change to the status indicated in the "LED indication" table below.

FUTABA CORPORATION

1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba-ken, 299-4395, Japan

Phone: +81 475 32 6982, Facsimile: +81 475 32 6983

©FUTABA CORPORATION 2012, 4 (1)

LED Indication

Green

Red

Status

Solid

Solid

Initializing when on "High Speed mode"

Off

Solid

No signal reception

Solid

Off

Receiving signals

Blink

Off

Receiving signals but ID is unmatched

Alternate blink

Unrecoverable error (EEPROM, etc.)

CH group table

CH group

LED blink

Port 1

Port 2

group 1

Red time

CH1

CH2

group 2

Red time

CH1

CH4

group 3

Red time

CH2

CH4

group 4

Green time

CH1

CH5

group 5

Green 2 time

CH2

CH7

group 6

Green 3 time

CH4

CH8

group 7

Red/Green time

CH11

CH12

group 8

Red/Green 2 time

not used

not used

group 9

Red/Green 3 time

not used

not used

Initial setting is group 1.

The groups 8 and 9 are not usually used.

3CH port and S.BUS port never change.

When using the R6303SBE Receiver with

the GYA430, 431 and CGY750

The following table corresponds to the gyro's functions. A port can be

used effectively. The servo which a gyro controls is connected to a gyro.

* Please refer to the description of each gyro manual.

S.BUS gyro group table

Gyro control CH

CH group

Rudder

group 1

Elevator

group 2

Aileron

group 3

Elevator+Rudder

group 4

Aileron+Rudder

group 5

Aileron+Elevator

group 6

Aileron+Elevator+Rudder

or CGY750

group 7

When S.BUS is used

* Set the channel of

S.BUS servos by using an SBC-1 channel changer, CIU-2

USB serial interface or the programming software in the

18MZ transmitter.

*

Can also be used together with conventional servos. However, conventional

servos cannot be used by the

S.BUS output.

*

When using servos with a remote battery pack, use

S.BUS Hub with Cable

(2-way/remote battery pack use).

Please refer to the instruction manual of

S.BUS Hub with Cable (2-way/re-

mote battery pack use) for the connection method.

*Turn on the power in transmitter→receiver order. In addition, always check

the operation of all the servos before flight.

*Do not insert or remove the servo connector while the receiver power is ON.

What is S.BUS?

S.BUS is different from conventional radio control systems in that it

uses data communication to transmit control signals from the receiver

to a servo, gyro, or other S.BUS compatible devices. The S.BUS

devices only execute only those comands for there own set channel.

This is why a single signal can be used to connect multiple servos.

How to Set the Operation Channel

It is possible to choose the operation channel mode of the port 1 and 2

from 7 setting groups.

1

Turn on the receiver. (At this moment, the transmitter should

be off.) Then, ensure the

LED is lit in RED or flashing green

light.

2

Press and hold the

Link/Mode button more than 5 seconds.

3

Release the button when the

LED blinks RED and GREEN

simultaneously.

4

The receiver is now in the "Operation CH Set" mode. At this

moment, the

LED indicates current set status through flashing

a pattern that corresponds to the CH group.

*Cannot exit this CH setting mode before the operation mode is fixed.
**See the below table that shows correspondence between "CH group" and way

of flashing LED.
***Default CH mode is "Group 1".

5

By pressing the

Link/Mode button, the operation CH is switched

sequentially as "group 1"  "group 2"  "group 3"....

6

The operation mode will be set by pressing the

Link/Mode

button more than 2 seconds at the desired CH group.

7

Release the button when the

LED blinks RED and GREEN

simultaneously. After releasing the button, the RED and

GREEN

LED are lit 1 second simultaneously. Then, the

operation CH is fixed.

8

After confirming the operation CH mode is changed, turn off

and back on the receiver power.

*The “Operation CH Set” mode cannot be changed during the receiver

communicates to the transmitter.

Advertising