2 framework and dimension – IC Realtime 3.0 MegaPixel 8-16mm VF IP66 IP Bullet/Box Camera with IR & POE (ICIPS3000AF) User Manual
Page 6

2
Port Name
Function
Connection Note
POWER
Power input
port
/
Power port. Input DC 12V or AC 24V.
Please note:
z
Connect the DC5.5 round port to 2-pin
converter cable (Provided) when you are
using AC 24V series product.
z
The DC5.5 round port to 2-pin converter
cable is not included in the accessories
bag if you are using DC 12V series product.
Please refer to the follow sheet for detailed pin information.
Port Name SN
Name
Note
1
ALARM_COM
Alarm output public port.
2
ALARM_NO
Alarm output port. It is to output the alarm signal to
the alarm device.
NO: normal open alarm output port.
3 ALARM_IN1
Alarm input port 1. It is to receive the on-off signal
from the external alarm source.
4
ALARM_IN2
Alarm input port 2. It is to receive the on-off signal
from the external alarm source.
I/O Port
5
GND
Ground port
1.2 Framework and Dimension
Please refer to the following figure for dimension information. The unit is mm. See Figure 1-2 and
Figure 1-3.
Figure 1-2