IFS MC201-1P/1FS User Manual 7

Note:

LFP function is turned-off by default. This feature can

also be enabled or disabled via the side DIP-switch. If the
installer is familiar with the network installation and diagnostics
(i.e. checking which end is broken in a connection), switch can
be set to ON position and converter should be reset for
changes to take effect. Otherwise, it's recommended to keep
the DIP switch in its default position.

Installing the Converter

Please follow these steps to install the MC201-1P/1FS:

1. Turn off the power of the network device/station in the

network to which the MC201-1P/1FS will be attached.

2. Ensure that there is no activity on the network.

3. Attach the fiber cable from the MC201-1P/1FS to the fiber

network. TX/RX must be paired at both ends.

4. Attach a Category 5 UTP cable from the 10/100Base-TX

network to the RJ-45 port on the MC201-1P/1FS.

5. Connect the 48V DC power adapter to the MC201-1P/1FS

and verify that the Power LED illuminates.

6. Turn on the network device/station, the TX Link and FX

Link LEDs should illuminate when all the cables are
attached.