- 2 -

Figure 5: Mounting on concrete
Always use a DV1202A mounting plate. The expansion plug must
penetrate at least 50 mm into the concrete. Please follow the steps
shown in Figure 6 if you are installing the test transmitter DV1215A.

$

For the equipment to conform to CEI standard 79-2, the
DV1215A test transmitter must be installed.

Figure 6: Control and function test
Using a voltmeter, check the background signal level in the detector
to prevent nuisance alarms. Set the sensitivity to Gmax during the
test.

DV1201A

DV1221A

Measure

0.7 V

0 V

None

1.4 V

2 V

Reduce range/remove source

$

Try to remove the source of ambient noise instead of
reducing the range.

Functional testing with hand tester DV1230

!

and mechanical

tool

"

:

DV1201A

DV1221A

Alarm in 30 sec.

Alarm in 45 sec.

Alarm after 5 blows

NA

Detection range (in foot):

Technical specifications:
Input power:

9-15 VDC
2 V max. ripple pp

Current consumption:

Nom. 8.6 mA

Alarm output:

Form C solid state relay, max. series
resistance 35 Ohm

Alarm indication:

LED-ind. output 3

Sensitivity:

5 steps of 6 dB each

Range:

See Table “Detection range”

Sabotage protection:

Temp. 183.2 °F
drill shield,
opening/pry-off contact,

Low voltage alarm:

7.5 V

Temperature limits:

-4 °F to + 131 °F

Dimensions:

3.93 x 3.15 x 1.30 inches

Colour:

Grey, RAL 7035

Weight:

0.86 lb

Concrete

13.12

45.93

45.93

Steel

1/G

max

26.25

45.93

45.93

Brick

9.84

26.25

26.25

Concrete

9.84

29.53

29.53

Steel

2/G

ref

13.12

29.53

29.53

Brick

3.28

19.69

19.69

Concrete

6.56

19.69

19.69

Steel

3/G

min

6.56

19.69

19.69

Brick

-

13.12

13.12

Concrete

3.28

16.40

16.40

Steel

4

3.28

16.40

16.40

Brick

-

9.84

9.84

Concrete

-

13.12

13.12

Steel

5

-

13.12

13.12

Brick

-

6.56

6.56

Sensitivity

setting

Material

Thermal

lance

Diamond

disk

Drilling