En: installation sheet, Introduction, Installation guidelines – Interlogix EV1116 User Manual

Page 3: Installing the detector, J3 j4

Advertising
background image

P/N 146251999-4 (ML) • REV D • ISS 12MAR13

3 / 32

7

EV1116

EV1116AM

EV1116

EV1116AM

Zo

ne

X

1

2

3

4

5

6

7

GND +12V

Ala

rm

Ala

rm

Ta

m

pe

r

WT

Ta

mper

J3

J4

8

D/N

CP

Zo

ne Y

+1

2V

Ta

m

pe

r

WT

Ta

m

pe

r

1

2

3

4 5

6

7

8

9

10

GN

D

Alarm

D/

N

AM AM

Al

arm

Z

o

ne X

J3

J4

11

Rt

es

t

CP

Z

o

ne Y

+12

V

Ta

m

per

WT

Ta

m

pe

r

1

2

3

4

5

6

7

8

9

10

GN

D

Ala

rm

D/N AM AM

Al

a

rm

Zo

n

e X

J3

J4

Z

one Y

+1

2V

Ta

m

p

er

WT

Ta

m

pe

r

GND

Al

a

rm

D/

N

AM AM

Ala

rm

Zone X

+

12V

Ta

mper

WT

Ta

m

pe

r

GND

Al

arm

D/

N

AM AM

Alarm

J3

J4

J3

J4

J3

J4

11

Rt

es

t

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

Rt

es

t

Rt

es

t

CP

CP

Z

one X

1

2

3

4

5

6

7

GND +12

V

Al

a

rm

Al

a

rm

Tam

per

WT

Ta

m

pe

r

J3

J4

Zone X

GN

D

+1

2V

Ala

rm

Ala

rm

Ta

mper

WT

Ta

m

p

er

GN

D

+12V

Al

arm

Al

arm

Ta

mper

WT

Ta

mper

GND +12

V

Al

arm

Al

a

rm

Ta

m

p

er

WT

Ta

m

pe

r

J3

J3

J4

J3

J4

8

D/

N

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

D/

N

D/

N

D/

N

J4

CP

(1)

( )

2

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

Ω

kΩ

Ω

8

8

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

Ω

kΩ

Ω

8

8

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

Ω

kΩ

Ω

8

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

Ω

kΩ

Ω

8

+1

2V

Ta

mper

WT

Ta

m

p

er

GN

D

Ala

rm

D/N

AM AM

Al

ar

m

Rt

es

t

Normal

larm

A

< 33 Ω

8

Normal

larm

A

< 33 Ω

8

EN: Installation Sheet

Introduction

The EV1116 series includes the EV1116 and EV1116AM PIR
motion sensors. They have a patented mirror, pyro and signal
processing technology.

Note:

EV1116AM has not been evaluated by UL.

Installation guidelines

The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:

•

Direct sunlight on the detector

•

Strong draughts onto the detector

•

Heat sources within the detector field of view

•

Animals within the detector field of view

•

Obscuring the detector field of view with large objects,
such as furniture

•

Objects within 50 cm (20 in.) of the anti-masking (AM)
detector

•

Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)

Installing the detector

Figure 7 legend

Item Description

(1)

Standard connection (factory default)

(2)

Dual loop connection

CP Control

panel

WT Walk

test

AM Antimasking

D/N Day/night

Rtest Remote

test

To install the detector:

1. Lift off the custom insert and remove the screw

(see Figure 2, step 1).

2. Using a screwdriver, carefully prise open the detector (see

Figure 2, steps 2 and 3).

3. Fix the base to the wall between 1.8 and 3.0 m (5.9 and

9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or C.

Advertising