En: installation sheet, Introduction, Installation guidelines – Interlogix EV1116 User Manual

Page 3: Installing the detector, J3 j4

Advertising
background image

P/N 146251999-4 (ML) • REV D • ISS 12MAR13

3 / 32

7

EV1116

EV1116AM

EV1116

EV1116AM

Zo

ne

X

1

2

3

4

5

6

7

GND +12V

Ala

rm

Ala

rm

Ta

m

pe

r

WT

Ta

mper

J3

J4

8

D/N

CP

Zo

ne Y

+1

2V

Ta

m

pe

r

WT

Ta

m

pe

r

1

2

3

4 5

6

7

8

9

10

GN

D

Alarm

D/

N

AM AM

Al

arm

Z

o

ne X

J3

J4

11

Rt

es

t

CP

Z

o

ne Y

+12

V

Ta

m

per

WT

Ta

m

pe

r

1

2

3

4

5

6

7

8

9

10

GN

D

Ala

rm

D/N AM AM

Al

a

rm

Zo

n

e X

J3

J4

Z

one Y

+1

2V

Ta

m

p

er

WT

Ta

m

pe

r

GND

Al

a

rm

D/

N

AM AM

Ala

rm

Zone X

+

12V

Ta

mper

WT

Ta

m

pe

r

GND

Al

arm

D/

N

AM AM

Alarm

J3

J4

J3

J4

J3

J4

11

Rt

es

t

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

11

Rt

es

t

Rt

es

t

CP

CP

Z

one X

1

2

3

4

5

6

7

GND +12

V

Al

a

rm

Al

a

rm

Tam

per

WT

Ta

m

pe

r

J3

J4

Zone X

GN

D

+1

2V

Ala

rm

Ala

rm

Ta

mper

WT

Ta

m

p

er

GN

D

+12V

Al

arm

Al

arm

Ta

mper

WT

Ta

mper

GND +12

V

Al

arm

Al

a

rm

Ta

m

p

er

WT

Ta

m

pe

r

J3

J3

J4

J3

J4

8

D/

N

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

D/

N

D/

N

D/

N

J4

CP

(1)

( )

2

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

kΩ

8

8

Normal

larm

A
Tamper
Short
AM/TF

4.7 k
9.4

0

kΩ

8

8

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

kΩ

8

Normal

larm

A
Tamper
Short

4.7 k
9.4

0

kΩ

8

+1

2V

Ta

mper

WT

Ta

m

p

er

GN

D

Ala

rm

D/N

AM AM

Al

ar

m

Rt

es

t

Normal

larm

A

< 33 Ω

8

Normal

larm

A

< 33 Ω

8

EN: Installation Sheet

Introduction

The EV1116 series includes the EV1116 and EV1116AM PIR
motion sensors. They have a patented mirror, pyro and signal
processing technology.

Note:

EV1116AM has not been evaluated by UL.

Installation guidelines

The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:

Direct sunlight on the detector

Strong draughts onto the detector

Heat sources within the detector field of view

Animals within the detector field of view

Obscuring the detector field of view with large objects,
such as furniture

Objects within 50 cm (20 in.) of the anti-masking (AM)
detector

Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)

Installing the detector

Figure 7 legend

Item Description

(1)

Standard connection (factory default)

(2)

Dual loop connection

CP Control

panel

WT Walk

test

AM Antimasking

D/N Day/night

Rtest Remote

test

To install the detector:

1. Lift off the custom insert and remove the screw

(see Figure 2, step 1).

2. Using a screwdriver, carefully prise open the detector (see

Figure 2, steps 2 and 3).

3. Fix the base to the wall between 1.8 and 3.0 m (5.9 and

9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or C.