Testing, Maintenance, Programming – Interlogix 60-807-01-95R User Manual

Page 3

Advertising
background image

Pet Immune SAW PIR Motion Sensor w ith Lithium Battery Installation Instructions

3

6. When testing is completed the PIR can be securely

attached to its mounting plate by screwing the smallest

enclosed screw into the mounting plate hole at the top of

the mounting plate (see Figure 7 below).

Setting the sensitivity on the indoor motion

sensor

For pet applications, the PIR must be set to standard

sensitivity.

Figure 6: Sensitivity pins locations

Testing

Walk Testing

Walk testing should be done to determine the sensor’s actual
coverage area. The edge of the coverage pattern is

determined by the first flash of the LED. This may change

slightly depending upon the sensitivity s etting. Walk test the

unit from both directions to determine the pattern boundaries.

1. Remove the sensor body from the mounted mounting

plate, activate the tamper switch, and then remount the

body to activate the 60 second walk test mode.

2. Walk across the coverage pattern to determine the

coverage area, indicated by LED activation. Each

activation extends the walk test mode for an additional 60

seconds.

After 60 seconds without motion the walk test mode times out

and the LED will no longer activate when motion is detected.

Caution:

Excessive use of the walk test mode may reduce

battery life. Use only for initial setup and maintenance testing.

Note: When the walk test mode has ended, an alarm can be

transmitted only after 3 minutes have passed since the

previous alarm. This 3 minute lockout time reduces

unnecessary RF transmissions in high traffic areas thereby

extending battery life.

Environment testing

Turn on all heating or air conditioning sources which would

normally be active during the protection period. Stand away

from the sensor and outside the coverage pattern and watch

for alarms.

Maintenance

At least once a year, the range and coverage should be

verified for proper operation. The end user should be instructed

to put the sensor in walk test mode and walk through the far

end of the coverage pattern to verify proper detection.

Replacing and Disposing of Batteries

The sensor is powered by 1 AA Lithium battery. When the

system indicates the sensor has a low battery, replace it

immediately.

When battery replacement is necessary, observe proper

polarity (as shown in the battery compartment) when installing

the new battery, or the sensor may be damaged. Be sure to

note that as you look at the battery compartment, on the le ft

side the positive battery end is down and on the right side the

positive end is up. When the battery is replaced, wait at least 3

minutes before activating the walk test mode.

Caution:

Replace only with 1 AA lithium battery. Observe

polarity when installing the new battery. Installing the battery

backwards may cause damage to the sensor. Dispose of used
batteries according to the manufacturer’s instructions, and/or
local government authorities. See Figure 7 below for the

battery location.

Figure 7: PIR com ponents

Programming

Refer to the panel installation instructions for information on

programming the sensor into the panel.