Input selection, Verifying rf communication, To verify – Interlogix 319.5 Crystal MaxLife Door User Manual

Page 2: Mounting, To mount the sensor

Advertising
background image

Figure 3. Board components

Tamper switch

Battery

holder

Reed A

Input

jumper

Reed B

Positive

External

Contact
Terminals

3. Set the panel to program mode.

4. Proceed to the Learn sensors menu.

5. Set the external contact in the alarm condition (see

External contact wiring

).

6. Press and release the tamper switch (

Figure 3

) on the

sensor until the panel responds.

7. Select the appropriate sensor group and number.

8. Exit program mode.

Input selection

Only one door/window input can be used at any given time. For
example, if the external contact is used, internal reed switches
(Reed A and Reed B in

Figure 3

) cannot be used.

Note: Power down the device before positioning the input
selection.

See

Figure 4

and position the input selection jumper to select:

Reed B. Left two pins covered (default).

Reed A. Right two pins covered.

External contact. Jumper removed.

Figure 4 Input selection jumper

Reed A

External contact

(default)

Reed B

Jumper

location

Verifying RF communication

Before mounting the sensor, verify the sensor mounting
location provides good RF panel communication.

To verify:

1. Put the panel/receiver into sensor test mode.

2. Take the sensor to the mounting location.

3. Hold the magnet next to the alignment mark on the sensor

(

Figure 5

) and then pull the magnet away from the sensor.

Figure 5. Alignment marks

Sensor end view

Sensor side view

Magnet

Alignment marks

4. Listen for siren beeps to determine appropriate response

(refer to the specific panel/receiver documentation).

5. Exit sensor test mode.

Mounting

To mount the sensor:

1. Remove the sensor battery.

2. Remove the circuit board from the sensor base by pulling

back on the plastic tab.

3. Mount the sensor base using the screws provided (

Figure

6

).

Figure 6. Mounting holes

Mounting

hole

Mounting

hole

Wire

entry

4. Replace the circuit board.

5. Remove the magnet from its base.

6. Line up the magnet alignment mark with the sensor

alignment mark, depending on the internal reed switch
being used (

Figure 5

).

7. Mount the magnet base with the #6 x 0.625 in. PPH

screws no more than 3/8 in. (0.95 cm) away from the
sensor base (

Figure 7

). Replace the magnet cover.

2

319.5 Crystal MaxLife Door/Window Sensor Installation Instructions

Advertising